To change a TR-069 parameter, use the following API:
rg_conf_set manufacturer/vendor_name CompanyName
rg_conf_set manufacturer/vendor_oui (Organizationally Unique
Identifier; AudioCodes' OUI is 00908F)
rg_conf_set manufacturer/product_class MP-20X
rg_conf_set manufacturer/model_number MP-202
rg_conf_set manufacturer/hardware/serial_num 123456
rg_conf_set cwmp/acs_url http://acsurl.com
rg_conf_set cwmp/username cpe
rg_conf_set_obscure cwmp/password 123456
rg_conf_set cwmp/conn_req_username acl
rg_conf_set_obscure cwmp/conn_req_password 123
If a parameter is changed, activate the following CLI commands:
rg_conf_set
reconf 1
To stop and restart the TR-69 client, use the following CLI
commands:
cwmp_session_start
cwmp_session_stop
Name
Type
Manufacturer
string(64)
OUI
string(6)
ProductClass
string(64)
SerialNumber
string(64)
User's Manual
cwmp/enabled
1
TR-069 Parameter Descriptions
Description
Manufacturer of the device (for display only).
Organizationally unique identifier of the device manufacturer.
Represented as a six hexadecimal-digit value using all upper-
case letters and including any leading zeros. The value MUST
be a valid OUI.
Identifier of the class of product for which the serial number
applies. That is, for a given manufacturer, this parameter is
used to identify the product or class of product over which the
SerialNumber parameter is unique.
Identifier of the particular device that is unique for the indicated
class of product and manufacturer.