Toshiba e-studio600 Service Manual page 67

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
In "RAM", the NVRAM or FRAM of the board in which the data of each code is stored is indi-
cated. "M" stands for the LGC board and "SYS" stands for the SYS board.
Classi-
Code
fication
200
Devel-
Automatic adjustment of
oper
auto-toner sensor
(Fuser heater ON)
201
Devel-
Correction of auto-toner
oper
sensor
(Fuser heater ON)
205
Devel-
Developer bias DC output
oper
adjustment
210
Charger Main charger grid bias out-
put adjustment
March 2005 © TOSHIBA TEC
Adjustment mode (05)
Default
Func-
<Accept-
Items
tion
ALL
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 43
05/05
RAM
Contents
able
value>
-
-
The adjustment starts
approx. 3 minutes after
this mode has been
selected, and then the
value is automatically
adjusted. The adjust-
ment value is fixed by
pressing the [ENTER]
button.
*
This selection is dis-
abled when the
developer unit is not
installed.
(Ch.3.1)
128
M
The adjustment value of
the auto-toner sensor set
in the code 05-200 is
verified.
*
This selection is dis-
abled when the
developer unit is not
installed.
113
M
The developer bias is
output. Use this code to
verify the output value of
the high-voltage trans-
former.
*
The value is output
while the developer
unit is taken off from
the drum.
(Ch.3.6)
102
M
The main charger grid
bias is output. Use this
code to verify the output
value of the high-voltage
transformer.
*
Take off the devel-
oper unit to enable
this code.
(Ch.3.6)
Proce-
2
dure
17
3
3
3