[E]
Primary scanning data laser writing start position at duplexing
Note:
Note:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
[E-1]
Adjustment for long-sized paper
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON. Æ (Adjustment Mode)
(1)
Press [3] Æ [FAX]. (A grid pattern with 10 mm squares is printed out. Use A3/LD in the 2nd/4th
(2)
drawer.
(3)
Check the grid pattern on the test print and measure the distance E from the left edge of the
paper to the 6th line of the grid pattern.
(4)
Check if the distance E is within 52±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance E again.
(Adjustment Mode) Æ (Key in code [498]) Æ [START] Æ [0] Æ [START]
Æ (Key in a value (acceptable values: 0 to 255))
Æ [ENTER] or [INTERRUPT] (Stored in memory)
Æ "100% A" is displayed.
Æ Press [3] Æ [FAX] Æ (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance E becomes (0.05 mm/step).
[E-2]
Adjustment for short-sized paper
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON. Æ (Adjustment Mode)
(1)
Press [3] Æ [FAX]. (A grid pattern with 10 mm squares is printed out. Use A4/LT in the 1st
(2)
drawer/tandem LCF.
(3)
Check the grid pattern on the test print and measure the distance E from the left edge of the
paper to the 6th line of the grid pattern.
(4)
Check if the distance E is within 52±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance E again.
(Adjustment Mode) Æ (Key in the code [498]) Æ [START] Æ [1] Æ [START]
Æ (Key in a value (acceptable values: 0 to 255))
Æ [ENTER] or [INTERRUPT] (Stored in memory).
Æ "100% A" is displayed
Æ Press [3] Æ [FAX] Æ (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance E becomes (0.05 mm/step).
<Adjustment procedure summarization for A to E>
[0] [5] [Power ON] Æ [1] ([3](05-445, 498) for duplex) Æ [FAX]
A:
05-401 (2nd/4th drawer, A3/LD)
B:
05-411 (2nd/4th drawer, A3/LD)
March 2005 © TOSHIBA TEC
Æ 200±0.5 mm
(e-STUDIO 520/600/720: 0.3 mm/step,
e-STUDIO 850: 0.1 mm/step)
Æ 52±0.5 mm (0.05 mm/step)