(8)
Measure the distance (L) between the stitching position and the folding position. Then, perform
"positive width adjustment" or "negative width adjustment" to suit the relationship between the
stitching position and the folding position.
If the stitching position is below the folding position, perform "positive width adjustment."
If the stitching position is above the folding position, perform "negative width adjustment."
Positive Width Adjustment
Negative Width Adjustment
March 2005 © TOSHIBA TEC
Mark
Unit: mm
Example: If L is 1 mm, provide "+1 mm".
Mark
Unit: mm
Example: If L is 0.5 mm, provide "-0.5 mm".
Fig.3-88
3 - 75
Folding position
Stitching position
Stitching position
Folding position