(9)
Match the rear hole of the right-hand hinge
and the hole of the equipment side to tighten
the stepped screw. If they do not fit, adjust
the position of the hole by turning the screw
of the adjustment plate.
(10) Tighten the stepped screw and 2 screws on
the adjustment plate.
Open and close the RADF to check again
that the positioning pins fit smoothly into the
holes on the RADF. Remove the positioning
pins after checking it.
(Replace the positioning pins at the rear of
the right-hand hinge of the RADF.)
(11) Place the platen sheet on the original glass
with the cutout on your right.
Align the platen sheet against the left and
rear side of the original glass. Close the
RADF slowly. Open the RADF to check that
the platen sheet is correctly attached.
March 2005 © TOSHIBA TEC
Screw of the
adjustment plate
Fig.3-57
2 screws: Half turn
Fig.3-58
Fig.3-59