Toshiba e-studio600 Service Manual page 255

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

(3)
Close the RADF to check that the positioning
pins fit smoothly into the holes on the RADF.
If they do not, adjust them according to the
following procedure.
(4)
Loosen the stepped screw 1 turn and 2
screws on the adjustment plate a half turn
(status of temporary fixing).
(5)
Remove the stepped screw at the rear of
right-hand hinge.
March 2005 © TOSHIBA TEC
Fig.3-51
2 screws: Half turn
Fig.3-52
Fig.3-53
e-STUDIO520/600/720/850 ADJUSTMENT
3 - 55
Stepped screw: 1 turn
3