Toshiba e-studio600 Service Manual page 37

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

Error code
Classification
CC50
Finisher related
service call
CC60
CCC1
CCD1
CCE1
CD00
Laser optical unit
related service call
CD10
Process related
service call
CD20
CD30
CD40
CD50
Fuser unit related
service call
CE50
Image quality con-
trol related service
call
CE90
CF70
Process related
service call
CF80
F070
Communication
related service call
F090
Other service call
F091
F092
F100
F101
F102
F103
F104
F105
F106
F107
F108
F110
Communication
related service call
F111
F120
Other service call
F130
F200
March 2005 © TOSHIBA TEC
Contents
Horizontal registration motor abnormality: The horizontal
registration motor does not run normally or the puncher
does not move normally.
Punch motor abnormality: The punch motor does not run
normally or the puncher does not move normally.
Communication error between Inserter Unit and Finisher
Inserter EEPROM abnormality
Inserter fan motor abnormality
Laser initialization time-out: Laser control does not end
within the initialization period.
[e-STUDIO850]
Cleaning brush drive motor abnormality: The cleaning
brush drive motor does not run normally when the power
is turned ON or the copying is started.
Used toner transport motor abnormality: The used toner
transport motor does not run normally when the power is
turned ON or the copying is started.
Recycle toner transport motor abnormality: The recycle
toner transport motor does not run normally when the
power is turned ON or the copying is started.
Toner bag full
Web motor signal path abnormality
Temperature/humidity sensor abnormality: The output
value of the temperature/humidity sensor is out of the
specified range.
Drum thermistor abnormality: The output value of the
drum thermistor is out of the specified range.
New toner transport motor abnormality: The new toner
transport motor does not run normally when new toner is
supplied.
Hopper motor lockup: The hopper motor does not run
normally when the power is ON or the copying is started.
Communication error between System-CPU and Engine-
CPU
SRAM abnormality on SYS board
FRAM abnormality on SYS board
SRAM and FRAM abnormality on SYS board
HDD format error: The HDD cannot be formatted nor-
mally.
HDD unmounted: Connection of the HDD is not detected.
HDD boot error: HDD does not become ready for booting.
HDD data transfer time-out: Data reading or writing is not
executed in a specified period of time.
HDD data error: Abnormality is detected in the data of the
HDD.
Other HDD errors
Point and Print partition damage
/BOX partition damage
/SHA partition damage
Communication error between System-CPU and Scan-
ner-CPU
Scanner response abnormality
Database abnormality: Databases do not run normally.
Invalid MAC address
Data overwrite kit (GP-1060) is taken off
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 13
05/11
Troubleshooting
Ch.5.1.12
Ch.5.1.12
Ch.5.1.12
Ch.5.1.12
Ch.5.1.12
Ch.5.1.11
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.8
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.9
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
Ch.5.1.9
Ch.5.1.9
Ch.5.1.13
Ch.5.1.13
Ch.5.1.13
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio720E-studio850E-studio520

Table of Contents