Toshiba e-studio600 Service Manual page 256

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

(6)
Remove the positioning pin at the front side.
Close the RADF to fit the positioning pin into
the hole at the rear side of the RADF. While
peering inside from the front side, fit the posi-
tions of the pin and hole by moving the
RADF right and left.
(7)
Tighten the positioning pin at the front side.
Close the RADF to fit the positioning pin into
the hole at the front side of the RADF. (For
the front side, adjust the RADF position all
around.)
(8)
While peering inside from the left side, close
the RADF. Check the positions of the holes
of the RADF and pins and then fit their posi-
tions by moving the RADF back and forth.
(For the front side, also adjust the RADF
position right and left.) Make sure not to dis-
locate the positions of the pin and hole at the
rear side.
e-STUDIO520/600/720/850 ADJUSTMENT
3 - 56
Fig.3-54
Fig.3-55
Fig.3-56
March 2005 © TOSHIBA TEC