Toshiba e-studio600 Service Manual page 511

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

(5)
Remove the cover plate.
(6)
Connect the download jig with the jig connector (CN6) on the scanning section control PC board
(SLG board).
(7)
Open the front cover.
(8)
Turn ON the power while [0] button and [8] button are pressed simultaneously.
Updating starts automatically and the LED on the download jig lights.
(9)
After the update is completed properly, the LED on the download jig blinks. The LED starts blink-
ing in approx. 20 sec. since the update starts. It is assumed that the update is failed if it does not
start blinking even though 1 min. has passed. In this case, turn OFF the power and check the fol-
lowing items. Then, clear the problem and restart updating from the beginning.
Is the download jig connected properly?
Is the ROM installed to the download jig properly?
Is the updating data written on the ROM of the download jig properly?
Do the download jig and the equipment operate properly?
(10) Turn OFF the power, remove the download jig and install the cover plate, the right upper cover
and the top right cover.
(11) Close the front cover.
March 2005 © TOSHIBA TEC
Cover plate
Fig.6-23
Connector
Fig.6-24
6 - 25
e-STUDIO520/600/720/850 FIRMWARE UPDATING
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio720E-studio850E-studio520

Table of Contents