11 Clamp FD Position Adjustment

Perform this adjustment for the width in vertical scanning direction of the body set.
To specify Clamp FD Position Adjustment
1
Touch [Adjustment] on the Machine Status Screen.
The Adjustment Menu Screen will be displayed.
2
Touch [04 Finisher Adjustment], [08 Perfect Binder Adjustment], and then [11 Clamp FD Position Adj.].
The Clamp FD Position Adjustment Screen will be displayed.
3
Display the required size key using up/down arrow keys to select the paper size of the body set to be
attached with the cover.
4
Touch [COPY] tab.
The Copy Screen will be displayed.
5
Select the PB tray or desired main body tray, then press [Start].
A sample pattern of perfect-bound book will be output.
6
Check that the vertical scanning direction is equal on all pages of the body set.
7
If the desired result cannot be obtained, touch [ADJUSTMENT] tab.
8
Touch [+ <--> -] to specify the value to be positive or negative. Use the touch panel keypad to enter the
desired adjustment value, then touch [<<SET].
Available range: -20 (wide) to +20 (narrow), 1 step = 0.1 mm
9
Repeat the adjustment steps from 3 to 8 until the desired result is obtained.
10
Touch [Return] to restore the Perfect Binder Adjustment Menu Screen.