ISC VALVE PRE-SET

When removing or replacing the ISC valve, set the ISC valve
using the following procedure:
PROCEDURE
1) Turn the ignition switch to the OFF position.
2) Remove the seat. (
3) Connect the special tool to the dealer mode coupler and turn
its switch to ON position.
09930-82720: Mode select switch
4) Turn the ignition switch to the ON position.
5) Turn the ignition switch to the OFF position.
6) Then, wait more than 5 seconds.
NOTE:
The ISC valve automatically is set at the PRE-SET position.
7) Turn the special tool to the OFF position and remove it from
the dealer mode coupler.
7-4)