REGULATOR/RECTIFIER
• Remove the right cowling. (!7-5)
• Disconnect the regulator/rectifier couplers 1.
• Remove the regulator/rectifier 2.
Measure the voltage between the terminals using the multi cir-
cuit tester as indicated in the table below. If the voltage is not
within the specified value, replace the regulator/rectifier with a
new one.
# 09900-25008: Multi circuit tester set
) Tester knob indication: Diode test (*)
B/R
B/R
B1
B2
B3
B/W
✽ 1.4 V and more (tester's battery voltage)
NOTE:
If the tester reads 1.4 V and below when the tester probes are not
connected, replace its battery.
+ Tester probe
B1
B2
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2
Unit: V
B3
B/W
0.4 – 0.7
0.4 – 0.7
0.4 – 0.7
ELECTRICAL SYSTEM 8-11
B/R
B2
B1
B3
B/W
B/R