The Solution 64 is capable of controlling up to 16 outputs. The
first 4 outputs are on the main control board and an additional
4 outputs are provided using an output expander module.
Each output can have its own unique name up to 16 characters
to identify it on the system for display and reporting purposes.
Under the commands menu you are able to view the status
of any input and to change its on/off condition. In the case of
latching output types, you will be required to reset the output
manually using these commands.
Outputs are programmed using an event table. First select the
event type that will cause the output to trigger. Then select
the polarity of the event, if it is low and goes high or high and
goes low. If the event is pulsing or one shot type, the time
parameter must also be programmed to define the time of the
pulse.
Event Assignment, this is extremely important parameter
and has a different meaning depending on the event type
selected. For example, event type "24 Area Part On" the event
assignment selects the Area that is armed in part on for the
output to trigger. If you set the event assignment to 1, then it
will correspond to area 1 and so on, setting it to zero means
all areas. See the event type table for more detail on the
relationship of event type to event assignment.
Outputs 1 and 2 are special outputs that can be configured
as horn speaker polarity types and are monitored to report
a device connection trouble. Output 4 is a dry relay contact
which has a optional jumper that allows you to switch positive
or negative without the need to add additional wiring.
The outputs are all protected and will shut down individually
under overload conditions. A report will be generated and a
displayed on the keypad to indicate the trouble condition.
O ut pu t Co m ma nd s
Outputs > Commands >
Output Status
This command allows you to view the current status of any
system output.
Press [MENU] + [4] + [0] + [0] and select the output you want to
1)
view from the list then press [OK]. Alternatively, you can
directly enter the output number that you want to view then
press [OK].
2)
The keypad will display the following when the output is
currently in the OFF state and ready to activate.
Bosch Secu-
Output Programming
-
-
-
MENU 4-0-0
Output 1 Name Op001
Is Off and Ready
Press OK or MENU
3)
The keypad will display the following when the output is
currently in the OFF state but the connection is missing.
Output 1 Name Op001
Is Off
Connection Trouble
Press OK or MENU
The keypad will display the following when the output is
4)
currently in the ON state and ready.
Output 1 Name Op001
Is On and Ready
Press OK or MENU
5)
The keypad will display the following when the output is
currently in the ON state but the connection is missing.
Output 1 Name Op001
Is On and Ready
Connection Trouble
Press OK or MENU
6)
Press [OK] or [MENU] to exit.
Outputs > Commands >
Turn Output On/Off
This command allows you to manuallly turn any output ON or
OFF. Outputs can be configured to control various functions
including outside lighting, pool pumps, watering systems, air
conditioners etc.
1)
Press [MENU] + [4] + [0] + [1] and select the output you want to
operate from the list then press [OK]. Alternatively, you can
directly enter the output number then press [OK].
2)
The keypad will display the following when the output is off. To
turn the Output On, press [ON].
S e c t ion 8
-
-
MENU 4-0-1
8-1