Fault Acknowledge All Areas
Setting this option allow system trouble faults to be acknowledged
from any area or keypad on the system without the need to toggle
over to the area the fault occurred in.
Delay Trouble Beeps
Setting this option will prevent any system trouble events from
sounding the keypad speaker between the hours of 10pm until 7am.
During this time, any new trouble events will be shown in the keypad
display.
If any trouble events are still in effect at 7am, the keypad will begin
sounding the trouble alert to notify the user of the problem. The func-
tion is primarily for use in residential installations.
System > Options >
Keypad Idle Screen
0 = No Idle Screen
1 = Date and Time
(*** System Wide Parameter ***)
This menu allows you to sellect a keypad Idle Screen which
will appear on the display when there has been no activity at
the keypad for a period of 2 minutes. The keypad display will
return to normal as soon as any key has been pressed.
The are two built-in Idle Screens and one custom Idle
screen which can be created and programmed only via the
SolutionLink upload/download software. The custom screen
can be used to display the Installer name and logo or other
information as required.
All keypads on the system will display the same screen saver.
See the examples below.
Press [MENU] + [7] + [7] + [2]. The keypad will display the
1)
current Keypad Idle Screen option.
Keypad Idle Screen
00 - No Idle Screen
Press  0-9 OK to SAVE
Use the up and down arrow keys to select which idle screen
2)
you want to display then press [OK] to save and exit or press
[MENU] to exit without saving.
Wed 05-Jan-2005
Time > 10:34am
10:34am
i
The custom idle screen can only be programmed via the
SolutionLink upload / download software.
Note
Bosch Security Systems | 11/05 |
MENU 7-7-2
2 = Time
3 = Custom Screen
System > Options >
Keypad Hi/Lo Temp
(*** System Wide Parameter ***)
This menu allows you to set the keypad High and Low
temperature values which the system will monitor. Valid
temperatures are from 00 ˚C minimum to a maximum of 50 ˚C
with a tolerance = +/- 1 ˚C.
If the temperature on the selected keypad falls below the
minimum set temperature then the keypad will display 'Low
Temp xx˚C If the temperature increases above the maximum
set temperature then the keypad will display High temp xx˚C.
Where xx = the set temperature to be monitored.
(*** System Wide Parameter ***)
0
Press [MENU] + [7] + [7] + [3]. The keypad will display the
1)
current temperature settings.
Keypad Hi/Lo Temp
High Temp
00
Press  OK to SAVE
2)
Use the up and down arrow keys to program the High and Low
temperatures. Use the left and right arrow keys to move
between the High and Low temperatures.
Valid range =( 0˚C to 50˚C).
3)
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Installer Options >
Installer Options
1
Report/Log Entry/Exit Intstaller Menu
2
Report/Log Program Data Change
3
Arm Only Installer PIN
4
Reserved
5
Auto Exit Installer Menu In 2 Hours
6
Auto Exit Service mode In 2 Hours
7
Reserved
8
Factory Defaulting Allowed
This menu allows you to configure the Installer system options.
(*** System Wide Parameter ***)
1)
Press [MENU] + [7] + [7] + [4]. The keypad will display the
current Installer options.
Report Installer
 Report Prog Change
Reserved
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
2)
press the [ON] key to enable or the [OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Solution 64 | Installer Guide | System Programming
-
0
0
˚C
Hi TEMP
Low Temp
00
MENU 7-7-3
0
0
˚C
Lo TEMP
MENU 7-7-4
N
Y
N
N
Y
Y
N
Y
11-13