Solution 64 | Installer Guide | Area Programming
Using the numeric keys, enter the new account number. Use
2)
the up and down arrows to select special characters BCDEF.
Account Dest 2 A001
1604000000
Press  0-9 OK to SAVE
Press [OK] to save and exit or press [MENU] to exit without
3)
saving.
Areas > Reporting >
Open / Close Route
0 = Report Events To Log Only
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs the destination for open and close
reports. Only one option can be programmed in this menu.
1)
Enter [MENU] + [2] + [2] + [2] and select the area from the list
then press [OK].
2)
Use the numeric keys 0-9 or the up and down arrow keys to
sellect the desired option.
Open/Close Route A001
01-Dest 1 + Log
Press  0-9 OK to SAVE
3)
Press [OK] to save and exit or press [MENU] to exit without
saving.
Area Tes ting
Areas > Area Testing >
Area Watch
(*** System Wide Parameter ***)
This menu programs the number of weeks (001 – 255 weeks /
000 = disabled) an area can remain disarmed before registering
an 'Inactivity Interval' report. A restore signal will be sent when
the area is next armed and the exit time expires.
1)
Enter [MENU] + [2] + [9] + [0] . The keypad will display the
current number of weeks programmed for area watch.
Area Watch
012 Weeks
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the number of weeks that an
area can remain turned off betore a trouble condition will
occur. Valid entries are 1 – 255 Weeks or 000 to disable.
3)
Press [OK] to save and exit or press [MENU] to exit without
saving.
6-6
Areas > Area Testing >
User Test Interval
(*** System Wide Parameter ***)
This menu sets the number of days before it will prompt the
user to walk test the system. To clear the trouble condition, you
will need to perform the 'Walk Test' function.
1)
MENU 2-2-2
1
2)
3)
Areas > Area Testing >
Service Interval
(*** System Wide Parameter ***)
This menu sets the number of weeks between service intervals.
When a service interval is due, a trouble condition will display
on the keypad to remind the customer that a system check is
required by the security company. When viewing the trouble
condition, the keypad will display 'Call For Service' . To clear the
trouble condition, the installer must enter and exit installer's
programming mode.
MENU 2-9-0
1)
0
1
2
WEEKS
2)
3)
Enter [MENU] + [2] + [9] + [1]. The keypad will display the
current number of weeks between User Test intervals.
User Test Interval
000 Days
Press 0-9 OK to SAVE
Using the numeric keys, enter the number of days between
each user test interval. Valid entries are 1 – 255 Days or 000 to
disable.
Press [OK] to save and exit or press [MENU] to exit without
saving.
Enter [MENU] + [2] + [9] + [2]. The keypad will display the
current number of weeks between user test intervals.
Service Interval
052 Weeks
Press 0-9 OK to SAVE
Using the numeric keys, enter the number of weeks between
each user Service Interval. Valid entries are 1 – 255 Weeks or
000 to disable.
Press [OK] to save and exit or press [MENU] to exit without
saving.
Bosch Security Systems | 11/05 | BLCC110I
MENU 2-9-1
0
0
0
DAYS
MENU 2-9-2
0
5
2
WEEKS