Bosch Solution 64 Installer's Manual page 94

Intrusion control panel
Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Solution 64 | Installer Guide | System Programming
System > Schedules >
Time
Start Time
12
:
00 am
HH
MM
This menu allows you to program the start time and stop time
of each schedule.
Enter [MENU] + [7] + [5] + [1] and use the up and down arrows
1)
to highlight the Schedule in the list then press [OK].
Alternatively, you can enter the Schedule number directly and
press [OK].
Sk001 Schedule 1 Name
Sk002 Schedule 2 Name
Sk003 Schedule 3 Name
Press  OK or MENU
2)
Using the arrow keys enter the required start and stop times in
12 hour format. To change from AM to PM scroll through the
hours using the up or down arrow keys.
Time Sk001
Start Time
12:00am
Press  OK to SAVE
3)
Press [OK] to save and exit or press [MENU] to exit without
saving.
i
If the start time equals the stop time then the schedule is
disabled. A time of 12:00AM or --:-- is disabled.
Note
System > Schedules >
Day
Sun Mon Tue Wed Thu Fri
Y
This menu allows you to program which days of the week the
schedule will operate. To enable the schedule on a particular
day press the the number 1 to 8 which corresponds to the
day. For example to enable Monday press [2] and to disable
Monday press [2] again.
1)
Enter [MENU] + [7] + [5] + [2] and use the up and down arrows
to highlight the Schedule in the list then press [OK].
Alternatively, you can enter the Schedule number directly and
press [OK].
Sk001 Schedule 1 Name
Sk002 Schedule 2 Name
Sk003 Schedule 3 Name
Press  OK or MENU
Press numbers [1] to [8] to enable/disable the days of the week
2)
that the schedule will operate.
11-10
-
MENU 7-5-1
Stop Time
12
:
00 am
HH
MM
Stop Time
12:00am
-
MENU 7-5-2
Sat Hol
Y
Y
Y
Y
Y
Y
Day Sk001
S M T W T F S Hol
y y y y y y y
Press 1-8 OK to SAVE
3)
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Schedules >
Function
0 = Disabled
1 = Area On/Off
2 = Area Part On/Off
This menu allows you to program what function the schedule
will perform. There are a number of options which are
explained in more detail below. Only one option can be
programmed.
Enter [MENU] + [7] + [5] + [3] and use the up and down arrows
1)
to highlight the Schedule in the list then press [OK].
Alternatively, you can enter the Schedule number directly and
press [OK].
Sk001 Schedule 1 Name
Sk002 Schedule 2 Name
Sk003 Schedule 3 Name
Press  OK or MENU
2)
Using the up and down arrow keys, select the schedule
function that you require then press [OK] to save and exit or
press [MENU] to exit without saving.
Function Sk001
00 - Disabled
Press  0-9 OK to SAVE
Disabled
Setting this option will disable the schedule.
Area On/Off
N
Setting this option will cause the system to turn ON at the START
time and turn OFF at the STOP time. Setting the Time to 12:00 am will
disable the function and you will see --:-- am on the display.
The INDEX is the AREA to turn on and/or off, setting the index to zero
will arm and disarm all areas.
Area Part On/Off
Setting this option will cause the system to turn ON in Part Mode 1
at the START time and turn OFF at the STOP time. Setting the Time
to 12:00 am will disable the function and you will see --:-- am on the
display.
The INDEX is the AREA to turn on and off in Part Mode, setting the
index to zero will arm and disarm all areas.
Operate Output
Setting this option will cause the system to operate the output at the
start time and turn the output off at the stop time. Setting the Time
to 12:00 am will disable the function and you will see --:-- am on the
display.
The INDEX is the Ouput Number to turn on and off, setting the index
to zero will disable the output.
N
MENU 7-5-3
3= Operate Output
4 = Timer Group
Bosch Security Systems | 11/05 | BLCC110I
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents