Bosch Solution 64 Installer's Manual page 82

Intrusion control panel
Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Solution 64 | Installer Guide | Device Programming
Using the numeric keys, enter the number of hours for the RF
2)
superSolution time. Valid times are 0 - 255 hours, 0 = No
SuperSolution.
Press [OK] to save and exit or press [MENU] to exit without
3)
saving.
Device > RF Devices >
RF Device Options
1
Display RF Tamper
2
Report RF Tamper
3
Report RF Low Battery
4
Report Lost RF Device
5
Open Zone On Lost RF
6
Audible Keyfob Panic
7
Report Keyfob Panic
8
Keyfob Function 1 Key = Part On
This menu option allows you to configure various options and
functions for RF devices connected to the system.
1)
Press [MENU] + [6] + [2] + [2]. The keypad will display the
current RF Device Options.
 Display RF Tamper
 Report RF Tamper
 Report RF Low Battery
Press  OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
3)
then press [OK] to save and exit or press [MENU] to exit
without saving.
Display RF Device Trouble
Setting this option will cause the keypad to display a trouble
condition when an RF device fails.
Report RF Device Tamper
Setting this option will cause the panel to send an RF Device Faulted
report to the base station when the devices tamper curcuit is tripped.
A restore report will be sent when the tamper circuit is resealled.
Report RF Device Low Battery
Setting this option will cause the panel to send a report to the base
station when the RF device signals to the panel that it has a low
battery condition.
Unseal Zone On RF Device Missing
Setting this option will cause the panel to show a zone fault on the
keypad for any RF devices that are missing.
Report RF Device Missing
Setting this option will cause the panel to send a report to the base
station if the panel detects that an RF device is missing.
Audible RF Key Fob Panic
Setting this option allows users who have RF keyfobs to trigger an
audible panic alarm via the keyfob.
10-6
Report RF Keyfob Panic
Setting this option will cause the panel to send a Panic report to the
base station when a panic alarm has been initiated via a key fob.
RF Keyfob Function Key 1 = 'Part On'
Setting this option will allow keyfob users to arm an area or all areas
of the system using function key 1 on the keyfob.
MENU 6-2-2
Y
Devices > RF Devices >
Y
Add RF Keypad
Y
Reserved for future use.
Y
Y
Delete RF Keypad
Y
Y
Reserved for future use.
Y
View RF I.D.
This command allows you to trap and view a transmitters I.D.
number when it has been forgotten or it is no longer legible
on the transmitter label. The device being tested must be
compatible with the RF receiver fitted to the panel.
1)
2)
3)
Press [MENU] + [6] + [2] + [5]. The system will then begin
waiting for a valid trigger signal.
Waiting for Trigger
Press OK or MENU
Trigger the transmitter by pressing any button on the keyfob
or by triggering the tamper switch on any sensor.
Type = Keyfob
RFID = 123456789
Press OK or MENU
To test another transmitter, repeat step 2. A beep will be heard
each time a new RFID is received and the new number will be
displayed.
Bosch Security Systems | 11/05 | BLCC110I
MENU 6-2-3
MENU 6-2-4
MENU 6-2-5

Hide quick links: