Solution 64 | Installer Guide | Comms Programming
Communication Test
Successful.
Press OK
3)
If the test fails, the keypad will prompt:
Communication Test
Fail.
Press OK
Press [OK] or [MENU] to exit.
4)
Comms > Comms Test >
Test Report Time
This menu programs the time of the day that the panel will
send the automatic Test Report to the base station receiver.
Automatic test reports are used to verify the panels ability to
report events via the telephone line on an ongoing basis.
1)
Press [MENU] + [5] + [9] + [1]. The keypad will display the
current Test Report Time.
Test Report Time
02:00am
Press  OK to SAVE
2)
Use the left, right, up and down arrow keys to select the Test
Report time required then Press [OK] to save and exit or press
[MENU] to exit without saving.
i
Scroll through the hours using the up and down arrow keys to
change the time from am to pm.
Note
Comms > Comms Test >
Test Report Period
0 = No Test Report
1 = Every Day
2 = Every Week
3 = Every Month
This menu programs how often the control panel will send a
test report. Only one option can be programmed.
(*** System Wide Parameter ***)
1)
Press [MENU] + [5] + [9] + [2]. The keypad will display the
current Test Report Period.
9-12
MENU 5-9-1
Test Time
02
:
00 am
HH
MM
MENU 5-9-2
Test Report Period
01-Every Day
Press 0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Test Report
Period then Press [OK] to save and exit or press [MENU] to exit
without saving.
Comms > Comms Test >
Test Report Options
1
Send Test Reports Only If No Other Report
2
Send Test Reports On Audible Time Out
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
1)
Press [MENU] + [5] + [9] + [3]. The keypad will display the
current Test Report Options.
Test if No other Report
 Test On Siren Reset
Reserved
Press  OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
3)
then press [OK] to save and exit or press [MENU] to exit
without saving.
Send Test Reports Only If No Other Report
Setting this option will cause the system to only send its automatic
Test report if no other area report has been sent within the test report
time period as programmed in MENU 5-9-2.
Send Test Reports On Audible Time Out
Setting this option will delay the Automatic Test Report if the sirens
are running when the test report time expires. This effectively keeps
the telco line free to make any further alarm reports which may be
triggered while the sirens are running. The panel will send the cued
Test Report as soon as the siren run-time has expired.
1
MENU 5-9-3
Bosch Security Systems | 11/05 | BLCC110I
N
Y
N
N
N
N
N
N