Solution 64 | Installer Guide | Input Programming
— Input Options
When pulse count hands over from one zone to another and
an alarm is triggered, a cross alarm report will be sent to the
central station.
Press [MENU] + [3] + [1] + [3]and use the up and down arrows
1)
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the current pulse count time for the chosen
zone.
Pulse Count Zn001
00
Press  0-9 OK or MENU
3)
Using the numeric keys, enter the number of pulses required.
Valid entries are 0 – 15 pulses.
Press [OK] to save and exit or press [MENU] to exit without
4)
saving.
Inputs > Zone Properties >
Pulse Count Time
This menu sets the time period during which the number of
zone trigger pulses must be received for an alarm to occur. The
zone must be set as a Pulse Count Zone for this time to have
any effect.
Press [MENU] + [3] + [1] + [4] and use the up and down arrows
1)
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the current pulse count time.
Pulse Count Time Zn001
120 Seconds
Press  0-9 OK or MENU
Using the numeric keys, enter the required Pulse Count Time.
3)
Valid entries are 0 – 255 seconds.
4)
Press [OK] to save and exit or press [MENU] to exit without
saving.
Unders tand i ng A cc e s s Gro u p s
Access Groups are used to link Readers, Users and Outputs
together to allow you to operate a door strike when a user
token is presented to a given reader. To do this you need to
create an access group and assign the user, the reader and the
output to the same access group.
Users
A user can belong to multiple Access Groups.
Outputs
An output can only belong to 1 Access Group.
Reader
7-6
A reader can belong to only 1 Access Group.
Access Group
There are 8 different access groups.
Door Access Group Example
1)
2)
3)
4)
When a user who belongs to Access Group 5 presents their
token to the reader that is assigned to Access Group 5, the
assigned output will operate releasing the door strike.
A reader can belong not only to a Access Group but also to an
MENU 3-1-4
Area if arming and disarming is required from the reader.
1
2
0
If a user presents their token to an reader that has an area
SECONDS
assigned, then the user Access Group and Area Permissions
are both checked. If the area is armed and the user belongs to
the same area as the Reader and the same Access Group, the
system will disarm and allow access.
If the user does not belong to the same area as the reader
but the Access Groups match, then door access will only be
available to that user if the area is disarmed.
When using the same reader for door access as well as arming,
you need to select the badging option MENU 1-6-3 — Reader
Options. Badging requires that you present your token 3 times
in succession within 5 seconds to arm the system.
Inputs > Zone Properties >
Access Group
1)
2)
3)
To set up a door access group you need to select an unused
Access Group number from 1 to 8, in this example we will
assume the Access Group number to be 5.
Under user properties assign the users who you wish to have
access to Access Group 5. Remember that you are able to
assign users to more than one Access Group.
Now select the output that will be used to operate the door
strike and assign it to Access Group 5. You also need to set the
output type to ACCESS and the polarity to one shot low with a
time of how long you would like the strike to operate.
Generally a strike would be operated for 5 seconds.
Assign the Reader under Reader properties to Access Group 5.
Press [MENU] + [3] + [1] + [5] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the current Access Group setting.
Access Group Zn001
00 - No Access Group
Press 0-9 OK or MENU
Use the up and down arrows to select the Access Group that
you want to assign the zone to.
Press [OK] to save and exit or press [MENU] to exit without
saving.