Solution 64 | Installer Guide | Section 2 - Installing the Hardware
P anel Add r e ss S e l ect
The Solution 64 pcb has three DIP switches (called Panel Node
Select) that must be set. In a multi-panel system, each control
panel (Node) must to be set to a unique address.
Panel NODE Select DIP Switch Address Settings
Panel to Address
Panel 1
Panel 2
Panel 3
Panel 4
Panel 5
Panel 6
Panel 7
Panel 8
Table 3 Panel Node Address Select
i
The node switch should be left at Panel 1 position for Solution
64. OFF-OFF-OFF
Note
The Graphic Keypad has 20, silicone rubber push button keys.
The buttons allow you to input instructions and navigate the
menu screens as required. Some buttons have a secondary
function which is activated by holding them down for two
seconds.
Each button's function is described below
K ey pa d Bu tton F un c t i o n s
Key
The numeric keys allow you to enter
to
numbers when required
Use the [MENU] and the numeric keys
to enter commands. The [MENU] key
is also used to go back one level when
navigating through menus or to exit a
programming location without saving
changes.
The [ON] key allows you to turn an area
or output on. To turn all areas on at the
same time when the system has been
partitioned, press and hold the [ON]
key for two seconds.
The [PART] key allows you to turn an
area Part On. This key can also be used
to bypass a zone or multiple zones
when you press and hold for two
seconds.
The [OFF] key allows you to turn an area
or output off. To turn all areas off at the
same time when the system has been
partitioned, press and hold the [OFF]
key for two seconds.
The [OK] key allows you to save any
changes and exit the command.
2-2
S1
S2
Off
Off
Off
On
Off
Off
Off
On
Off
On
On
Off
Off
Off
On
On
Off
On
Off
On
On
On
On
On
Description
Key
S3
+
for 2 sec
+
for 2 sec
+
for 2 sec
Ke yp ad Ins tallatio n a nd Setup
The Solution 64 control panel can have a maximum of 8
keypads connected via the LAN terminals. Each keypad must
be set to a unique address before they will operate and you will
also need to set the keypad home address in MENU 6-1-3.
Set each keypad address using the table below as a guide.
i
Only 1 Keypad can be assigned to each address.All Keypads are
supplied from the factory set to address 1. OFF-OFF-OFF.
Note
Ke yp ad A dd ress Selec tio n
Description
The [MAIL] key allows you to read
stored mail. This key can also be used
to initiate a dialler test when you press
and hold for two seconds.
The [] key allows you to move the
cursor to the left when programming
text or telephone numbers.
The [] key allows you to move the
cursor to the right when programming
text or telephone numbers.
The [↑] key allows you to navigate
through menus or to toggle characters
when programming text or telephone
numbers.
The [] key allows you to navigate
through menus or to toggle characters
when programming text or telephone
numbers. Pressing the [] key when the
area is disarmed will display any current
trouble conditions.
Pressing the 1 and 3 keys together and
holding them down for 2 seconds will
cause a Panic alarm to be triggered. If
programmed the sirens will sound and
the monitoring station will be notified.
Pressing the 4 and 6 keys together and
holding them down for 2 seconds will
cause a Fire alarm to be triggered. If
programmed the sirens will sound and
the monitoring station will be notified.
Pressing the 7 and 9 keys together and
holding them down for 2 seconds will
cause a Medical alarm to be triggered. If
programmed the sirens will sound and
the monitoring station will be notified.