Comms Registration; Comms Testing - Bosch Solution 64 Installer's Manual

Intrusion control panel
Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Comms > Dialler Reporting >
Swinger Dialler
(*** System Wide Parameter ***)
Swinger Dialler can be used to prevent a faulty or run-a-way
PIR from continually re-triggering the zone and reporting to
the base station.
The Swinger Dialler count sets the maximum number of times
an individual zone can trigger an alarm during the current
arming cycle before it is locked out.
If this option is not programmed, the panel will continue to
report the alarm signal until the system or area is disarmed.
Only zones that have been programmed for Lockout Dialler in
MENU 3-1-7 — Report Options will follow the Swinger Dialler
count.
1)
Press [MENU] + [5] + [4] + [5]. The keypad will display the
current Swinger Dialler count.
Swinger Dialler
6
Press 0-9 OK to SAVE
Using the numeric keys, enter the new Swinger Dialler count
2)
then press [OK] to save and exit or press [MENU] to exit
without saving. Valid entries are 0 - 15 / 0 = disabled
Comms > Dialler Reporting >
Burg Report Delay
(*** System Wide Parameter ***)
This menu programs how long the panel will delay reporting
Burglary alarm reports. Only burglary (non-fire) zones that
have been programmed for Delay Report in MENU 3-1-7 —
Report Option will follow the Burglary Report Delay time.
1)
Press [MENU] + [5] + [4] + [6]. The keypad will display the
current burglary report delay time.
Burg Report Delay
000 seconds
Press 0-9 OK to SAVE
2)
Using the numeric keys, enter the new report delay time then
press [OK] to save and exit or press [MENU] to exit without
saving. Valid entires are 0 to 255 seconds.
Bosch Security Systems | 11/05 | BLCC110I
Comms > Dialler Reporting >
MENU 5-4-5
Fire Report Delay
0
6
(*** System Wide Parameter ***)
This menu programs how long the panel will delay reporting
fire zone alarm reports. Only fire zones that have been
programmed for Delay Report in MENU 3-1-7 — Report Option
will follow the Fire Report Delay time.
1)
2)
C omms Reg istratio n
Comms > Registration >
Customer
Reserved for future use.
Comms > Registration >
Installer
MENU 5-4-6
0
0
0
Reserved for future use.
SECONDS
C omms Testin g
Comms > Comms Test >
Send Test Report
This menu allows you to test the reporting functions of the
Solution control panel by manually sending a Test report to
the receiving party (i.e. security company monitoring station,
mobile telephone etc).
1)
2)
Solution 64 | Installer Guide | Comms Programming
Press [MENU] + [5] + [4] + [7]. The keypad will display the
current Fire Report Delay time.
Fire Report Delay
000 seconds
Press 0-9 OK to SAVE
Using the numeric keys, enter the new report delay time then
press [OK] to save and exit or press [MENU] to exit without
saving. Valid entires are 0 to 255 seconds.
Enter [MENU] + [5] + [9] + [0]. The keypad will prompt that it is
in the process of sending a test report.
Comms Testing in
progress. Please wait.
To Go Back Press OK
If the test is successful, the keypad will prompt:
MENU 5-4-7
0
0
0
SECONDS
MENU 5-5-0
MENU 5-5-1
-
-
MENU 5-9-0
9-11