Solution 64 | Installer Guide | Comms Programming
Comms > Dialler Reporting >
TX Format Dest 2
0 = Disable
1 = Contact ID
7 = Domestic
2 = SIA
8 = Voice
3 = Serial STU
9 = Panel 1 (Node 1)
4 = GSM
10 = Panel 2 (Node 2)
5 = WEB MAIL
11 = Panel 3 (Node 3)
6 = SMS
12 = Panel 4 (Node 4)
This menu allows you to program the transmission format
or language the panel will use to send event reports to
Destination 2.
1)
Press [MENU] + [5] + [4] + [1]. The keypad will display the
current Transmission Format for Destination 2.
TX Format Dest 2 N001
01-Contact ID
Press 0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Transmission
Format required then Press [OK] to save and exit or press
[MENU] to exit without saving.
i
Transmission Formats 9 -12 are not applicable on the Solution
64 control panel and should not be programmed. Other
formats may require additional hardware or add on modules to
Note
function.
Comms > Dialler Reporting
Test Route
0 = Report Events To Log Only
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs which destination will be used to send
both manual and automatic test reports.
(*** System Wide Parameter ***)
1)
Press [MENU] + [5] + [4] + [2]. The keypad will display the
current Test Route.
Test Route
01-Dest 1 + Log
Press 0-9 OK to SAVE
2)
Use the up and down arrow keys to select the Test Route
required then Press [OK] to save and exit or press [MENU] to
exit without saving.
9-10
Comms > Dialler Reporting
MENU 5-4-1
Status Route
1
13 = Reserved
14 = Reserved
15 = Reserved
This menu sets the report destination that will be used to send
all system event reports.
(*** System Wide Parameter ***)
1)
2)
Comms > Dialler Reporting
Emergency Route
This menu programs the destination that all Keypad
MENU 5-4-2
emergency alarms are reported.
1
(*** System Wide Parameter ***)
1)
2)
0 = Report Events To Log Only
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Press [MENU] + [5] + [4] + [3]. The keypad will display the
current Status Report route.
Status Route
01-Dest 1 + Log
Press 0-9 OK to SAVE
Use the up and down arrow keys to select the Test Route
required then Press [OK] to save and exit or press [MENU] to
exit without saving.
0 = Report Events To Log Only
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Press [MENU] + [5] + [4] + [4]. The keypad will display the
current Emergency Route.
Emergency Route
01-Dest 1 + Log
Press 0-9 OK to SAVE
Use the up and down arrow keys to select the Keypad
Emergency route required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Bosch Security Systems | 11/05 | BLCC110I
MENU 5-4-3
1
MENU 5-4-4
1

Hide quick links: