Output Programming; Keypad Buzzer; Warning Device 1 / Oc1 Output; Warning Device 2 / Oc2 Output - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
Zone Type
7
8
9
10
11
12
13
10.5

Output Programming

10.5.1

Keypad Buzzer

Location 370
Keypad beeps when siren on 1=Disable, 1=Enable
10.5.2

Warning Device 1 / OC1 Output

Output 1
Event type (fixed value)
Polarity Mode (0=Steady, 1=Pulse)
Output Duration (001-999sec/000=on)
NOTICE!
When the triggered zone is programmed as silent zone, keypad output and OC1 output do not
response. Other outputs are as normal.
10.5.3

Warning Device 2 / OC2 Output

Output 2
Event type (Refer to output events option)
Polarity Mode (0=Steady, 1=Pulse)
Output Duration (001-999sec/000=on)
10.5.4

Optional Relay Output / OC3

Optional Relay Output
Event Type (Refer to output events option)
Polarity Mode (0=Steady, 1=Pulse)
Output Duration (001-999sec/000=on)
10.5.5

DX3010 Output

Location
Relay Output 1
Event Type (Refer to output events option)
Bosch Sicherheitssysteme GmbH
Description
24-Hour
Tamper
Fire
External Fault
Bolt Contact
Key Switch Toggle
Key Switch on/off
Installation Manual
Programming sheets | en
Location Default
370
0
Location Default
EN
3
371
EN=0
0
372-374
000
EN=180
Location Default
375
EN=3
3
376
EN=0
0
377-379
000
EN=180
380
0
381
0
382-384
030
Location Default
385
0
F.01U.241.127 | V4 | 2011.12