Service Data
Battery
CAUTION
!
Never use anything except the specified battery.
Item
Type designation
Capacity
Standard electrolyte S.G.
Generator
Item
Generator coil resistance
Generator maximum output
Generator no-load voltage
(When engine is cold)
Regulated voltage
Tightening Torque Specifications
Fastening part
Generator stator set bolt
CKP sensor mounting bolt
Generator rotor bolt
NOTE
The specified tightening torque is also described in the following.
"Regulator / Rectifier Construction (Page 1J-8)"
Reference:
For the tightening torque of fastener not specified in this section, refer to "Tightening Torque Specifications in Section
0C (Page 0C-7)".
Specifications
Specification
FT12A-BS
12 V, 36.0 kC (10 Ah)/10HR
1.330 at 20 °C (68 °F)
Specification
0.2 – 0.8 Ω
Approx. 400 W at 5 000 r/min
60 V (AC) and more at 5 000 r/min
14.0 – 15.5 V at 5 000 r/min
Tightening torque
N⋅m
kgf-m
11
1.1
11
1.1
120
12.0
Charging System:
B718H11A07001
Note
Note
B718H11A07002
Note
lb-ft
8.0
(Page 1J-6)
8.0
(Page 1J-6)
87.0
(Page 1J-6)
1J-13