Suzuki GSF1250 Service Manual page 12

Hide thumbs Also See for GSF1250:
Table of Contents

Advertisement

00-7 Precautions:
3) Measure resistance between terminal at one end of
circuit ("A" terminal in figure) and body ground. If
continuity is indicated, there is a short circuit to
ground between terminals "A" and "C".
"A"
"A"
"D": To other parts
4) Disconnect the connector/coupler included in circuit
(coupler "B") and measure resistance between
terminal "A" and body ground. If continuity is
indicated, the circuit is shorted to the ground
between terminals "A" and "B".
"A"
"D": To other parts
"D"
"B"
ECM
"C"
"E"
5V
"C"
I705H1000008-01
"E": Other parts
"D"
ECM
"B"
"C"
I705H1000009-02
Using The Multi-Circuit Testers
• Use the Suzuki multi-circuit tester set.
• Use well-charged batteries in the tester.
• Be sure to set the tester to the correct testing range.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
Using the testers
• Incorrectly connecting the (+) and (–) probes may
cause the inside of the tester to be burned.
• If the voltage and current are not known, make
measurements using the highest range.
• When measuring the resistance with the multi-circuit
tester (1), ∞ will be shown as 10.00 MΩ and "1"
flashes in the display.
• Check that no voltage is applied before making the
measurement. If voltage is applied the tester may be
damaged.
(A)
I649G1000024-03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsf1250aGsf1250sGsf1250sa

Table of Contents