Battery Components; Battery Charging - Suzuki GSF1250 Service Manual

Hide thumbs Also See for GSF1250:
Table of Contents

Advertisement

4) Measure the voltage between the terminals using the multi-circuit tester as indicated in the following table. If the
voltage is not within the specified value, replace the regulator/rectifier with a new one. Refer to "Regulator /
Rectifier Construction (Page 1J-8)".
NOTE
If the tester reads 1.4 V and below when the tester probes are not connected, replace its battery.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Diode test (
)
Unit: V
B/R
1
B/R
2
B
1
(–) probe of
B
2
tester to:
B
3
B/W
1
B/W
2
*1.4 V and more (tester's battery voltage)
5) Connect the regulator/rectifier couplers and bind the clamp.

Battery Components

5
4
3
2
1
1. Anode plates
2. Separator (Fiberglass plate)
3. Cathode plates
4. Upper cover breather
B/R
B/R
1
2
0
0
*
*
*
*
*
*
*
*
*
*
B718H11A06007
6
7
8
I649G11A0046-03
5. Stopper
6. Filter
7. Terminal
8. Safety valve
B/W
B/R
1
1
B/R
B/W
2
2
B
2
B
1
B
3
I718H11A0034-01
(+) probe of tester to:
B
B
1
2
0.2 – 0.8
0.2 – 0.8
0.2 – 0.8
0.2 – 0.8
0.6 – 1.2
0.6 – 1.2
0.6 – 1.2
0.6 – 1.2
0.3 – 1.0
0.3 – 1.0
0.3 – 1.0
0.3 – 1.0

Battery Charging

Initial Charging
Filling electrolyte
NOTE
When filling electrolyte, the battery must be
removed from the vehicle and must be put on
the level ground.
Charging System:
B
B/W
3
1
0.2 – 0.8
0.4 – 1.0
0.2 – 0.8
0.4 – 1.0
0.6 – 1.2
0.2 – 0.8
0.6 – 1.2
0.2 – 0.8
0.2 – 0.8
0.3 – 1.0
0.3 – 1.0
0
1J-9
B/W
2
0.4 – 1.0
0.4 – 1.0
0.2 – 0.8
0.2 – 0.8
0.2 – 0.8
0
B718H11A06008