Utility <Administrator Setting>
15.2
1 System Setting
15.2.1 1 Power Save Setting
Specify the interval of time to elapse before the machine automatically oper-
ates Low Power and Sleep.
Select either Low Power or Sleep as Power Save function to be activated
when the [Power Save] key on the control panel is pressed, and also select
whether or not to immediately return to the power saving condition after re-
ceiving a fax transmission during the Power Save mode.
To specify Power Save Setting
0 Low Power setting: 1 to 240 min. in 1 min. increments; factory default 15
min. (bizhub 500)/ 1 min. (bizhub 420)
0 Low Power will not function if the period of time specified for Low Power
exceeds the Sleep setting.
0 Sleep setting: 1 to 240 min. in 1 min. increments; factory default 90 min.
(bizhub 500)/ 15 min. (bizhub 420)
0 If the period of time selected for Sleep is longer than the Low Power set-
ting, Low Power operates first, then Sleep will take it over.
If the Sleep setting is shorter than the Low Power setting, Low Power
does not function while Sleep keeps operating.
bizhub 500/420
15
15-25