Item
TONER MOTOR M ON
Version 3 2008.05.30
NOTE: This procedure is for the technical staff. The customer check
are the procedure 1, 5 and 6.
When performing operation for five minutes or longer with the front
cover open, remove all toner cartridges, and cover the drum to avoid
exposure to light.
1)
Turn on the power and enter the CE Diag.
2)
Open the Front Cover.
3)
Remove the magenta toner cartridge.
4)
Cheat the safety Interlock System.
5)
Execute the TONER MOTOR M ON. (The customer can con-
firm the motor noise only.)
6)
Click the stop button to stop test.
7)
Remove the cheater.
8)
Replace the magenta toner cartridge.
9)
Close the Front Cover.
2 - 88
Chapter 2 Operation of Diag.
Confirmation procedure
Zna02025KA