Epson TM-U950 Technical Manual page 204

Hide thumbs Also See for TM-U950:
Table of Contents

Advertisement

CONFIDENTIAL
3. Attach the microswitch to the holder-N.E. detection by positioning hole
then secure the switch with the screw.
4. Place a nut on each holder-N.E. detector.
Checkpoints
For N.E. detector-J assembly, make sure to attach the nut on the holder marked with
and attach the microswitch so that the terminal faces mark
For N.E. detector-R assembly, make sure to attach the nut on the holder marked with
and attach the microswitch so that the terminal faces mark
Verify that the nuts are installed correctly with their curved surfaces facing outward.
5-66 Disassembly, Assembly, and Adjustments
N.E. detector-J assembly
N.E. detector-R assembly
over hole
d
.
a
.
b
;
e
,
b
,
a
Rev. A

Hide quick links: