Sub-assembly L-(1)
15. Mount the detector-carriage sub-assembly so that it is flush with the round dowel and long
16. Engage the FPC on the cable clasp. Mount the guide-nose onto the print head unit, and then
17. Plug the FPC into the board-head relay assembly.
Rev. A
dowel, as shown in the illustration. Then tighten the screw.
attach them and tighten the screw.
Checkpoint
Verify that the FPC is not deformed.
Verify that the print head unit is in contact with the ground plate.
Carriage-head assembly
Disassembly, Assembly, and Adjustments 5-25
TM-U950/U950P Technical Manual
Detector-carriage sub-assembly