IBM 6400 Setup Manual page 245

Line matrix printers cabinet and pedestal models
Table of Contents

Advertisement

Fault Message
136 PLATEN INVALID
PARAMETER
SEE SETUP GUIDE
137 SHUTTLE INVALID
COMMAND
SEE SETUP GUIDE
138 SHUTTLE INVALID
PARAMETER
SEE SETUP GUIDE
139 SHUTTLE OVERSPEED
SEE SETUP GUIDE
990 MACHINE CHECK
NON–VOLATILE MEMORY
FAILED
A97 GRAPHIC CHECK
ERROR
PRESS STOP THEN START
ENERGY SAVER MODE
ACTIVE
HAMMER COIL BAD
#, #, #
NOT READY
Table 11: Fault Messages
Operator
Explanation
Correctable?
No
Fatal firmware error on
the controller board.
No
Fatal firmware error on
the controller board.
No
Fatal firmware error on
the controller board.
No
Fatal firmware error on
the controller board.
N/A
Host status message.
No
Non–volatile memory
fault.
Yes
Printer has received a
non–printable character.
N/A
Status message: printer
is in low–energy idle
state, all fans and higher
voltages are off, only
+5Vdc logic circuits are
active.
No
Malfunction of one or
more hammer coils.
N/A
Printer state message:
printer is offline, not in
communication with
host.
Fault Correction Procedure
Solution
Contact your IBM service
representative.
Contact your IBM service
representative.
Contact your IBM service
representative.
Contact your IBM service
representative.
No action necessary.
Contact your IBM service
representative. NOTE: You
can still print, but you
cannot save configuration
changes as the NVRAM is
defective.
Press Stop then Start.
No action necessary.
NOTE: If the printer was in
NOT READY state when
the energy saver mode
was activated, it will remain
in the NOT READY state
until the START key is
pressed.
(You can continue to print
with degraded print
quality.) Contact your IBM
service representative.
No action necessary.
245