8.3
Adjusting the spreading
2
X
1
Caution: Danger of injury!
Exercise utmost caution when making adjustments with
the machine running.
Standard checking
The distance X between the clamping plates 2 and the fabric support
plate 1 should amount to 1.3 mm (non-spreaded) and to 0.3 mm
(spreaded).
–
Insert the clamping plates 2 and switch the machine on.
–
Press key "F".
–
Enter code "2548".
–
Press key "OK".
The control switches to the technician level.
–
Select menu "Test functions".
–
Press key "OK".
–
Select menu "Multitest".
–
Press key "OK".
–
Select menu "Output test".
–
Press key "OK".
–
Select function "Y03" (closing the fabric clamp).
–
Press key "OK".
The fabric clamps close.
–
Check whether the distance X amounts to 1.3 mm.
–
Select function "Y04".
–
Press key "OK".
The clamping plates spread.
–
Check whether the distance X amounts to 0.3 mm.
4
3
23