DURKOPP ADLER 580 Operating Instructions Manual page 111

Single-chainstitch automat for stitched eyelets
Hide thumbs Also See for 580:
Table of Contents

Advertisement

Error
2152
2153
2155
2156
2162
2201
2202
2252
2253
2255
Info/Description
Step motor X-axis excess
current
Step motor X-axis excess
voltage
Too high mains voltage
· Step motor X-axis
overcharge
· Step motor X-axis
blocked/moves too heavy
· Step motor X-axis
defective
· Control defective
· Step motor X-axis
excess temperature
· Step motor X-axis
moves too heavy
· Step motor X-axis
defective
· Control defective
· Step motor X-axis
IDMA Autoincrement
· Malfunction
· Step motor Y-axis
timeout reference
· Cable to the reference switch
faulty
· Reference switch defective
· Step motor Y-axis
Current supply fault
· Step motor Y-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Step motor Y-axis
excess current
· Step motor Y-axis defective
· Control defective
· Step motor Y-axis
excess voltage
· Too high mains voltage
· Step motor Y-axis
overcharge
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
· Control defective
Remedy
· Exchange step motor X-axis
· Exchange the control
Check the mains voltage
· Eliminate the blocking/rough
running
· Exchange step motor X-axis
· Exchange the control
· Eliminate rough running
· Exchange step motor X-axis
· Exchange the control
· Switch the machine off and on
again
· Exchange the cable
· Exchange the reference switch
· Eliminate the blocking
· Check /
exchange the encoder cable
· Exchange step motor Y-axis
· Exchange step motor Y-axis
· Exchange the control
· Check the mains voltage
· Eliminate the blocking/rough
running
· Exchange step motor Y-axis
· Exchange the control