29.4.3
Menu item thread monitor (Thread mon.)
29.4.4
Menu item duty cycle of cutting block (Cut. time)
In this menu the needle thread monitor is set.
The set value means:
0
= Thread monitor switched off
1 ... 14
= Number of stitches after which the sewing
process is aborted because of thread breakage
Input:
0 ... 14
Standard: 7
The duration of the incision can be set individually so that the material
to be processed is cut open accurately and no longer than required.
Input:
200 ... 600
Standard: 200