DURKOPP ADLER 580 Operating Instructions Manual page 112

Single-chainstitch automat for stitched eyelets
Hide thumbs Also See for 580:
Table of Contents

Advertisement

Error
2256
2262
2301
2302
2352
2353
2355
2356
2362
108
Info/Description
· Step motor Y-axis
excess temperature
· Step motor Y-axis
blocked/moves too heavy
· Step motor Y-axis defective
Control defective
· Step motor Y-axis
IDMA Autoincrement
·Malfunction
· Step motor Z-axis
timeout reference
· Cable to the reference switch
faulty
·Reference switch defective
· Step motor Z-axis
Current supply fault
· Step motor Z-axis
blocked
· Encoder cable not
connected/defective
· Encoder defective
· Step motor Z-axis
excess current
· Step motor Z-axis defective
· Control defective
· Step motor Z-axis
excess voltage
· Too high mains voltage
· Step motor Z-axis
overcharge
· Step motor Z-axis
blocked/moves too heavy
· Step motor Z-axis defective
· Control defective
· Step motor Z-axis
excess temperature
· Step motor Z-axis
moves too heavy
· Step motor Z-axis defective
· Control defective
· Step motor Z-axis
IDMA Autoincrement
· Malfunction
Remedy
· Eliminate the blocking/rough
running
· Exchange step motor Y-axis
· Exchange the control
· Switch the machine off
and on again
· Exchange the cable
· Exchange the reference switch
· Eliminate the blocking
· Check/
exchange the encoder cable
· Exchange step motor Z-axis
· Exchange step motor Z-axis
· Exchange the control
· Check the mains voltage
· Eliminate the blocking/rough
running
· Exchange step motor Z-axis
· Exchange the control
· Eliminate the rough running
· Exchange step motor Z-axis
· Exchange the control
· Switch the machine off and on
again

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents