26.3 Subsequent fitting of the thread catcher
1
9
10 11
Caution: Danger of injury !
Mount the thread catcher only with the machine switched off.
If a thread catcher is mounted subsequently, the pneumatic
base plate 1 has to be supplemented by three valves.
–
Screw off the covers of the valve locations 9, 10 and 11 and screw
on the solenoid valves delivered with the mounting kit.
–
Mount the thread catcher 2.
–
Lay compressed air lines from the solenoid valves to the thread
catcher.
Valve 9 = thread catcher down (3).
Valve 10 = open the thread catcher (4).
Valve 11 = swivel the thread catcher to the front (5).
1
5
4
3
3
2
79