Menu Item Output Test - DURKOPP ADLER 580 Operating Instructions Manual

Single-chainstitch automat for stitched eyelets
Hide thumbs Also See for 580:
Table of Contents

Advertisement

29.6.1

Menu item output test

Attention: Danger of breakage !
The switching of output elements can lead to collisions
with other machine elements as well as to damages to the
automatic buttonholer.
Before switching on an output element make sure that this cannot
collide with other components.
Caution: Danger of injury!
Exercise utmost caution when making the output test with
the machine running.
In this menu the individual output elements can be engaged.
Select the desired output element with the keys "ñ" or "ò" .
The current status is shown in the display:
0 = Output inactive
1 = Output active
Press key "OK".
The output is converted.
Output
Designation
Y01
Needle thread trimmer, with 580-112000 and 580-312000
additionally looper thread cutter
Y02
Looper thread tension
Y03
Fabric clamp
Y04
Spreading
Y05
Needle thread puller
Y06
Cutter
Y07
Cutter
Y08
Looper thread pulling, only 580-121000/ 580-321000
Y09
Needle thread catcher (material)
Y10
Open the needle thread catcher
Y11
Needle thread catcher (needle)
Y12
Looper thread cutter, only 580-121000 /
580-141000/ 580-321000
Y13
Knife Multiflex, only 580-312000/ 580-321000
Y14
Cutting block Multiflex, only 580-312000/ 580-321000
Y15
Cutter
Quit the output test with key "ESC".