Rvon-C Default Setup - RTS Cronus Manual

Digital intercom matrix
Hide thumbs Also See for Cronus:
Table of Contents

Advertisement

78

RVON-C Default Setup

The board is shipped from the factory containing the following:
All are set rvon commands
Variable
Environment Name
ip_addr
EMACA_IPADDR
netmask
EMACA_NETMASK
gateway
EMACA_GW
serial_ip
RVON_SERIAL_IP
serial_baud
RVON_SERIAL_ Baud
user
RVON_USER
password
RVON_PASSWORD
vad_threshold
RVON_THRESHOLD_VAD
There are more parameters that the software will auto-configure if they have not been previously setup. The user can also set
these parameters, in which case the software would not modify but take them as they are.
All are set chan # commands because they are for each audio channel.
Variable
Environment Name
dest_ip
RVON_DEST_IP_#
dest_type
RVON_DEST_TYPE_3
dest_chan
RVON_DEST_CHAN_#
chan_codec
RVON_CHAN_CODEC_#
Typing printenv, then pressing Return from an RVON-C boot code or sys-printenv from the MXP Debug System Prompt may
show these commands. The Environment name is listed because this is the label used by the software.
IMPORTANT:
If the user is attempting to do a setenv to change a parameter from the RVON-C boot code, the
Environment Name must be used and not the set rvon variable name.
Bosch Security Systems, Inc.
Default Value
x.x.x.x
IP Address for the RVON-C Card
255.255.255.0
Network Mask for the RVONC card
none
Gateway IP Address for the RVON-C Card
none
Pass-thru serial port IP Address for the RVON-C Card
9600
Set the pass-thru serial port baud rate for the RVON-C
Card
telex
RVON-C user name for telnet access
password
RVON-C password for telnet access (8-40 characters)
10
VAD Threshold
Default Value
X.X.X.X
Destination IP Address for this particular RVON_CH
X
Destination Type Y= 0 (RVON-C), 1 (rvon-1), 2 (rvon-I/
O)
X
Destination Channel - what port of far end (0-7)
X
Profile to use (previous coding table)