8 Introduction Cronus
USB Connectors (front end and back end J7)
Connector Type ............................................ Standard USB
Ethernet Interface Port (J8)
Connector Type ........................................... RJ-45 standard
GPIO Interface Port (J9)
Connector Type: 25-pin Female D-sub
Pin 1......................................................................... Input 1
Pin 2......................................................................Common
Pin 3......................................................................... Input 2
Pin 4......................................................................Common
Pin 5......................................................................... Input 3
Pin 6......................................................................Common
Pin 7......................................................................... Input 4
Pin 8......................................................................Common
Pin 9............................................................................ GND
Pin 10.......................................................................... GND
Pin 11 .......................................................................... GND
Pin 12.......................................................................... +5 V
Pin 13.......................................................................... +5 V
Pin 14................................................................Relay 1 NC
Pin 15................................................................Relay 1 NO
Pin 16....................................................................Common
Pin 17................................................................Relay 2 NC
Pin 18................................................................Relay 2 NO
Pin 19....................................................................Common
Pin 20................................................................Relay 3 NC
Pin 21................................................................Relay 3 NO
Pin 22....................................................................Common
Pin 23................................................................Relay 4 NC
Pin 24................................................................Relay 4 NO
Pin 25....................................................................Common
NOTE:
The pin out of this connect does not confirm to
the standard pin out of Zeus, Zeus II, ADAM
CS, or ADAM and cannot be connected
directly to the GPI connector of the RVON I/O.
It requires a custom cable assembly.
Hotlink Connectors
Coax Type (J10 - J11 .................................RG6 BNC Female
..........................................................75 Ohm coax connector
Fiber Optic Type.............................................. HFCT-5208M
Bosch Security Systems, Inc.
10 Base-T (Cat 3) /
100 Base Tx (Cat5)
(single mode transceiver)
- 1300 nm laser based
transceiver in standard 1 x 9
mezzanine package for links
of 15km nominal with single
mode fiber cables.
Technical Manual
The fiber cable recommended for Cronus Single mode SM
SC-SC Duplex type. Two SC-SC simplex pair will work, but
you will have to verify which end to connect to each other.
Physical
Dimensions........................................19w x 3.5h x 14 deep
(482.6mm x 88.9mm x 355.6mm)
Weight ........................................ 14.15lbs (6.41 kilograms)
Environment
Operating...............................0°C to 50°C (32°F to 122°F)
Storage ............................... -20°C to 75°C (-4°F to 167°F)

GPIO-16

The maximum number of devices that can be connected
when using a GPIO-16 are as follows:
Zeus, Zeus II, and ADAM CS = Four (4) devices (64 relays)
ADAM and Cronus = 16 devices (256 relays)
For more information on the GPIO-16, see the GPIO User
Manual (F.01U.193.288).
F.01U.118.890
Rev. 23