Status Menu; Status, Azedit - RTS Cronus Manual

Digital intercom matrix
Hide thumbs Also See for Cronus:
Table of Contents

Advertisement

Cronus
Turn the ENC1 knob to set the threshold level (-127dB to 0.0dB)
7.
Double-tap the ENC1 knob to exit the threshold set menu item.
8.
Port displays.
Turn the ENC1 knob to Hold Time.
9.
Tap the ENC1 knob.
10.
Hold Time appears.
Turn the ENC1 knob to set the hold time (up to 12.5 seconds).
11.
NOTE: Hold time is the amount of time the VOX will stay active on a port before closing the port.
Double-tap the ENC1 knob to exit the Hold Time menu item.
12.
Port displays
Turn the ENC1 knob to Enable.
13.
Tap the ENC1 knob.
14.
Enable appears. You can Enable or Disable from this point.
Double-tap the ENC1 knob to exit the Enable menu item.
15.
NOTE: You can also set the VOX within AZedit. For more information about setting VOX in AZedit see "Vox
Settings in AZedit" on page 23.

Status Menu

The Status Menu displays settings for the following:
AZedit
Crosspoints
Frames
GPI Input
GPI Output
Keypanels
Links
NOTE:
This chapter covers the menu display for the Master frame (Frame 1). On slave frames, the only display you see
under Status menu is Links.

Status, AZedit

AZedit displays if there is an active connection.
NOTE:
This only shows the status of the primary serial cable.
To show the status, do the following:
Turn the ENC1 knob to scroll to Status.
1.
When Status is displayed, tap the ENC1 knob.
2.
AZedit displays.
Tap the ENC1 knob
3.
The status of AZedit appears.
OK = there is a connection to AZedit.
-- = there is no connection to AZedit.
Bosch Security Systems, Inc.
Technical Manual
Cronus Menu Structure 17
F.01U.118.890
Rev. 23

Advertisement

Table of Contents
loading