26 Cronus and AZedit
Window Item
Threshold Level
display box
Threshold adjust
slider
Set To
button
Hold Time
Adjust
arrow keys
Hold Time
display box
Hold Time Adjust
slider
Set To
button
Options
Show Enabled
check box
Only
Bosch Security Systems, Inc.
Field Type
The Threshold Level display box displays the threshold level selected by
the slider bar below.
The Threshold Adjust slider allows you to set the vox threshold by moving
the slider right (increase) or left (decrease).
NOTE:
>
Slide the
selected.
The
Set To
button must be clicked to accept the threshold level.
>
Once the threshold slider is at the desired threshold level, click
To.
Use the
UP
active from meeting the threshold level set above. Once a port meets or
exceeds its threshold level, the hold time determines how long that port will
stay active before closing (up to 12.5 seconds). You can see the adjustments
in the parameter display window (to the right)
You can select multiple ports to change at the same time. However, when
you increase or decrease the hold time of multiple ports the time changes
from each port's starting point. For example, Port 002 has a hold time of 0.7
seconds and Port 010 has a hold time of 1.0. If both are selected and the
hold time is increased by clicking the up arrow twice the ending threshold
for each port would be as follows:
Port 002 = 1.7 seconds
Port 010 = 2.0 seconds
The
Hold Time
slider bar below.
The Hold Time Adjust slider allows you to set the time by moving the
slider right (increase) or left (decrease).
NOTE: This sets the threshold to the level you set by the slider bar. It
>
Slide the
selected ports.
The
Set To
button must be clicked to accept the hold time.
>
Once the hold time slider is at the desired level, click
The
Show Enabled Only
ports in the display list to the right. When the check box is cleared,
enabled
all ports are displayed.
Technical Manual
Description
This sets the threshold to the level you set by the slider bar. It
does not increase or decrease the threshold from the individual
port starting dB.
bar to the level you want to set the port (s)
threshold slider
button activates the Threshold Level slider selection. The Set To
or
arrow keys to increase or decrease the time the port is
Down
display box displays the hold time level selected by the
does not increase or decrease the threshold from the individual
port starting dB.
bar to the level you want to set the
hold time slider
button activates the Hold Time slider selection. The Set To
check box, when selected displays only the
Cronus
Set
Set To.
Vox
F.01U.118.890
Rev. 23

Advertisement