  • Page 1 Cronus Digital Intercom Matrix Rev. 23 June/2013 F.01U.118.890...
  • Page 2 WARNING: APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS. RTS Intercoms ......www.rtsintercoms.com/warranty RTS Digital RTSTW WARNING: THE MAIN POWER PLUG MUST REMAIN READILY OPERABLE.
  • Page 3: Important Safety Instructions

    Cronus Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  • Page 4 Cronus Bosch Security Systems, Inc. Rev. 23 F.01U.118.890 Technical Manual...
  • Page 5: Table Of Contents

    DIP Switch Settings ..........................10 Cronus System Diagram and Frame Cabling ..................11 Default Jumper Settings for the Master Controller Board ..............12 Default Jumper Settings for the Cronus AIO Board ................13 CRONUS MENU STRUCTURE ....................15 Configure Menu .............................15 Set Frame ID ..................................15 IFB Program INs ................................
  • Page 6 Specifications ............................42 DIGITAL .....................................42 CONNECTIONS - PINOUTS .............................42 RVON-C JUMPERS and CONNECTIONS ........................42 Installation of the RVON-C Card into the Cronus System ..............45 Addresses and the RVON-C Card ............................45 Software Requirements ..........................45 Switches and Connections ........................46 Configuring the RVON-C Card with AZedit ..................47 RVON-C Connection Status Window ....................49...
  • Page 7 XCP-48-RJ45 Breakout Panel .......................88 XCP-48-Telco Breakout Panel ......................90 Telco Backcard Telco Connector J1, J4 ................................ 91 CRONUS MASTER CONTROLLER CARD ................93 Legacy Master Controller Card Jumper Settings ...................93 ADDITIONAL INFORMATION ....................95 RVON TRUNKING CONNECTIONS ..................97 Notes ..............................105 Technical Manual F.01U.118.890...
  • Page 8 Cronus Technical Manual F.01U.118.890 Bosch Security Systems, Inc. Rev. 23...
  • Page 9 FIGURE 33. CS9500 Trunking Via RVON-I/O To RVON-8 ............. 100 FIGURE 34. ADAM Trunking Via RVON-8 ..................101 FIGURE 35. Zeus II Trunking Via RVON-I/O to RVON-C ............... 102 FIGURE 36. Cronus Trunking Via RVON-I/O To RVON-8 .............. 103 FIGURE 37. RVON-16 Trunking ......................104 Bosch Security Systems, Inc.
  • Page 10 Cronus F.01U.118.890 Technical Manual Rev. 23 Bosch Security Systems, Inc.
  • Page 11: Introduction

    RTS Cronus is a 32-port digital matrix intercom in 2 RU (rack units). Based upon an advanced DSP (Digital Signal Processor) architecture, Cronus has the ability to link up to four (4) units into a single 128 port matrix. Through the use of standard video coaxial cable, the maximum distance between the first and last Cronus system can be up to 300ft., and still appear as a single...
  • Page 12: Differences Between Cronus And Adam

    Front and Rear Panel Controls and Connections There are two Cronus backcards, an MDR backcard and an RJ-12 backcard. You can have up to four backcards installed on Cronus. You can have any combination of backcards on the Cronus, too (for example, you can have two RJ-12 backcards and two MDR backcards Controls, Connections, and Cronus backcard.
  • Page 13 NOTE: Only one USB connector can be used at a time. Power 1& Power 2 – The power source indicator is a green LED light displaying the power is on. The Cronus has a redundant power source. This means there are two (2) power supplies, so it power supply 1 fails, power supply 2 takes over powering the system.
  • Page 14: Cronus Gain Structure

    6 Introduction Cronus Cronus Gain Structure Cronus Gain Structure. FIGURE 2. The table below shows the gain level adjustments for Cronus, ADAM and Zeus. Input Gain Output Gain Max Audio MAX Audio Cross Point Control Range Control Range Max Input Gain...
  • Page 15: Specifications

    Cronus Introduction 7 Specifications J2: RS-232 (Debug) Pin 1 ..............Not Used Analog Inputs and Out puts Pin 2 ................GND Signal Type ............balanced Pin 3 ............... Input RS-232 Nominal Level ............8dBu Pin 4 ..............Not Used Maximum Level............20dBu Pin 5 ..............Not Used Input Impedance ...........
  • Page 16: Gpio-16

    8 Introduction Cronus USB Connectors (front end and back end J7) The fiber cable recommended for Cronus Single mode SM Connector Type ..........Standard USB SC-SC Duplex type. Two SC-SC simplex pair will work, but you will have to verify which end to connect to each other.
  • Page 17 Cronus Introduction 9 MDR Connector MDR Connector PORT FUNCTION PORT FUNCTION Audio To Matrix - Data + Audio From Matrix + Data - Audio From Matrix - Audio To Matrix + Audio To Matrix - Data + Audio From Matrix +...
  • Page 18: Determining The Master System From The Slave Systems

    Determining the Master System From the Slave Systems By default, Cronus is set to operate in standalone mode. You will need a license file to link Cronus frames together. In order to link two (2) or more Cronus systems together, each must have the optional linking firmware installed. To purchase the firmware, contact RTS sales.
  • Page 19: Cronus System Diagram And Frame Cabling

    FIGURE 5. The Cronus intercom system has four (4) frames, one (1) Master and three (3) Slave stations (see system diagram on left) connected via coaxial cables (see cabling diagram at right). Each frame can support up to 32 ports, and each system can have a maximum of 128 ports (all four frames available).
  • Page 20: Default Jumper Settings For The Master Controller Board

    Write Protect Flash Chips IC11 and IC12 (Config Flash) Populate jumper across pins 2 and 3. NOTE: If you have board 9030-7785-000, see “Cronus Master Controller Card 9030-7785-000” on page 93 for the Default Jumper settings. Technical Manual Bosch Security Systems, Inc.
  • Page 21: Default Jumper Settings For The Cronus Aio Board

    Cronus Introduction 13 Default Jumper Settings for the Cronus AIO Board Cronus AIO Board 9030-7784-000 FIGURE 8. Jumper Description Default Setting 5 volt Power Isolation Populate Jumper across J1 Populate Jumpers across J2: Pins 5-6 DSP Debug Port Pins 7-8...
  • Page 22 14 Introduction Cronus Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 23: Cronus Menu Structure

    Set Frame ID In a single frame Cronus system, the frame is always Stand Alone (or the Master frame). In a multi-frame system, the first time Cronus is powered on, each frame shows as Frame 1 and will need to be configured, either manually or by auto-config, to designate which frame it is.
  • Page 24: Ifb Program Ins

    Use the ENC1 knob to adjust the IN Gain. Use the ENC2 knob to adjust the OUT Gain. NOTE: You can change the gain levels in AZedit and see the results on Cronus almost immediately. For more information on gain levels, see Figure 2 on page 6.
  • Page 25: Status Menu

    Cronus Cronus Menu Structure 17 Turn the ENC1 knob to set the threshold level (-127dB to 0.0dB) Double-tap the ENC1 knob to exit the threshold set menu item. Port displays. Turn the ENC1 knob to Hold Time. Tap the ENC1 knob.
  • Page 26: Status, Crosspoints

    The Crosspoint status appears. Status, Frames Frames displays the status of each of the Cronus frames. It tells if the frame is still active or if it has been deactivated. To display the frame status, do the following: Turn the ENC1 knob to scroll to Status.
  • Page 27: Status, Gpi Input

    Zeus, Zeus II, and ADAM CS = 4 devices (64 relays) • ADAM and Cronus = 16 devices (256 relays) For more information on the GPIO-16, see the GPIO User Manual (F.01U.193.288). To display the GPI Input status, do the following: Turn the ENC1 knob to scroll to Status.
  • Page 28: Status, Keypanels

    Status, Links The Links menu displays the status of the links (connections) between frames, see “Cronus System Diagram and Frame Cabling” on page 11. Each frame in the system has two (2) links, Link A and Link B. Link A on each frame connects to the preceding frame (connecting to Link B).
  • Page 29: Cronus Menu System Quick Reference

    FIGURE 9. To open the Cronus menu system, do the following: On the front panel of the Cronus system, tap the ENC1 encoder knob. The word Status appears. Turn the ENC2 encoder knob clockwise to scroll forward or counter-clockwise to scroll backwards through the list of menus.
  • Page 30 22 Cronus Menu Structure Cronus Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 31: Cronus And Azedit

    Cronus or AIO-16 at a preset threshold level, the audio lines are open for conversation between ports. With Cronus, you can set the Vox threshold from the front panel or you can set it through AZedit. In AZedit there are two(2) ways to access the Vox Settings window.
  • Page 32: Accessing Vox

    24 Cronus and AZedit Cronus Accessing Vox To access the Vox Settings window from the System menu, do the following: From the System menu in AZedit, select Vox. The Vox Settings window appears. NOTE: You can change the threshold levels and hold times of more than one port at a time by pressing the CTRL key and clicking the ports you want to change.
  • Page 33 Cronus Cronus and AZedit 25 Vox Settings window Figure 1. Window Item Field Type Description Threshold Adjust arrow keys Use the arrow keys to increase or decrease the vox threshold DOWN by.5 dB (-127dB to 0.0dB). You can see the level adjustments in the parameter display window (to the right).
  • Page 34 26 Cronus and AZedit Cronus Window Item Field Type Description Threshold Level display box The Threshold Level display box displays the threshold level selected by the slider bar below. Threshold adjust slider The Threshold Adjust slider allows you to set the vox threshold by moving the slider right (increase) or left (decrease).
  • Page 35 Real-Time Changes Changes Vox and hold time dynamically on the connected device (Cronus or AIO- 16). NOTE: When making adjustments from the front panel of the Cronus take into consideration that AZedit has a five (5) second display refresh rate which causes a delay in the application’s...
  • Page 36: Download Cronus License File

    To link more than one Cronus system together, you must have linking software installed on the system (normally, this is loaded at time of purchase). If you are adding a Cronus Intercom System to an existing Cronus matrix, you may need to load a license file on your existing system.
  • Page 37: Ethernet Setup For Cronus

    CHAPTER 4 Ethernet Setup for Cronus Default IP Addresses Product Default IP Address Default Subnet RVON-I/O 192.168.0.1 255.255.0.0 RVON-8 192.168.0.2 255.255.0.0 RVON-1 192.168.0.3 255.255.0.0 RVON-2 192.168.0.3 255.255.0.0 RVON-C 192.168.0.4 255.255.0.0 RVON-16 192.168.0.5 255.255.0.0 GPIO-16 192.168.0.6 255.255.0.0 MCII-e 192.168.0.7 255.255.0.0 Cronus 192.168.0.8...
  • Page 38: Connecting Cronus To The Pc And The Network

    The PC must be running version 2.06.07 or later of AZedit and have an Ethernet card installed. Verify Cronus is connected to the PC using either a USB (universal) or RS-232 (ADAM standard) cable. The USB drivers can be found in the AZedit software directory (C:\Telex\AZedit|V20701|USB). You may only use one USB connection (front panel or back panel) at a time.
  • Page 39: Download Firmware For Cronus

    Download Firmware for Cronus When firmware is downloaded to Cronus, all the code is put on the Master Controller card. This includes code for the AIO cards. Therefore, because the Master Controller downloads the firmware for the system and the code for the AIO cards, the download time is extended while the Master Controller pushes the AIO code out to the appropriate cards.
  • Page 40 From the Status menu, select Software Versions, then Master Controllers. The Master Controller Version Information window appears. Highlight the Cronus version to be updated. You may select more than one version at a time by holding the CTRL key down while you select.
  • Page 41: Finding The Mac Address For Cronus

    The Ethernet Setup window appears. The MAC Address aappears at the bottom of the window. NOTE: If you have multiple Cronus systems linked together, you need to individually connect them to the PC to see the MAC address. You cannot look at multiple Cronus MAC Addresses at the same time.
  • Page 42 34 Ethernet Setup for Cronus Cronus Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 43: Final Assembly Drawing

    Final Assembly Drawing Cronus Final Assembly - see Table 2, “Final Assembly,” on page 37 for descriptions to the corresponding numbers. FIGURE 10.
  • Page 45 MDR SCSI Master Controller Assembly 9020-7770-000 Coax Link Module Card Plate 9110-7784-008 Screw, FH, 6-32 x 3/8” LG. 51847-022 Cronus Fiber Link Module PCB 9030-7827-000 AI/O PC Board Assembly 9030-7784-000 Fiber Link Module Card Plate 9110-7784-011 Card Guide 6” LG...
  • Page 46: Technical Manual F.01U.118.890 Rev

    Cronus Wiring Diagram for Cronus FIGURE 11. Bosch Security Systems, Inc. Technical Manual F.01U.118.890 Rev. 23...
  • Page 47 Cronus FIGURE 12. Wiring Diagram Rev. 23 Bosch Security Systems, Inc. Technical Manual F.01U.118.890...
  • Page 48 Cronus Rev. 23 F.01U.118.890 Technical Manual Bosch Security Systems, Inc.
  • Page 49: Rvon-C Rts Voice Over Network For Cronus

    Installed directly into the Cronus Intercom frame, the RVON-C provides voice over IP (Internet Protocol) communications for the RTS Cronus intercom system. In general, voice over IP means sending voice information in digital form using discrete packets rather than the traditional telephone network. The RVON-C delivers an integrated solution for connecting custom keypanels to the Intercom Matrix over standard IP networks by supporting eight (8) channels (ports) of audio in and out.
  • Page 50: Specifications

    42 RVON-C RTS Voice Over Network for Cronus Cronus Specifications DIGITAL Digital Specifications TABLE 3. COMPRESSION BIT RATE CODING DELAY PLAYOUT DELAY BANDWIDTH G.711 125μs 20-60 ms 160-224 kbps G.728AB 10 ms 20-120 ms 32-112 kbps G.723 5.3K / 6.3 K...
  • Page 51 Cronus RVON-C RTS Voice Over Network for Cronus 43 Pin 1 J10, J11, and J12 Front card - RVON-C 9030-7835-000 FIGURE 13. Bosch Security Systems, Inc. Technical Manual F.01U.118.890 Rev. 23...
  • Page 52 44 RVON-C RTS Voice Over Network for Cronus Cronus J1 Serial J2 Serial RVON-C Backcard FIGURE 14. RVON-C Backplate FIGURE 15. Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 53: Installation Of The Rvon-C Card Into The Cronus System

    • When inserting the RVON-C card into the Cronus system, make sure to insert it into a compatible backcard. If the card is inserted into a incompatible backcard, undesirable results can occur.
  • Page 54: Switches And Connections

    46 RVON-C RTS Voice Over Network for Cronus Cronus Switches and Connections IMPORTANT: You must remove the card from the frame in order to change any DIP switch settings on the front card, see Figure 16 on page 46. DIP Switch 1 Closed: Configuration via AZedit is disabled.
  • Page 55: Configuring The Rvon-C Card With Azedit

    Cronus RVON-C RTS Voice Over Network for Cronus 47 Configuring the RVON-C Card with AZedit Once the RVON-C card is inserted into the Intercom, AZedit automatically recognizes the card. NOTE: Requires intercom firmware and AZedit software that support RVON cards.
  • Page 56 48 RVON-C RTS Voice Over Network for Cronus Cronus From the RVON-C drop down list, select the slot in which the RVON-C card resides, if it is not already selected. In the IP Address field, enter the IP Address you have assigned to the RVON-C card.
  • Page 57: Rvon-C Connection Status Window

    Cronus RVON-C RTS Voice Over Network for Cronus 49 RVON-C Connection Status Window The RVON-C Connection Status windows display information pertaining to RVON-C channel connections. You can show statistics for only one channel on a card at a time. NOTE: To view the RVON-C Connection Status windows make sure both AZedit and the RVON-C card are on the same Ethernet network.
  • Page 58 50 RVON-C RTS Voice Over Network for Cronus Cronus The Connection Status window contains six pages of information about the selected channel and are described in detail on the following pages. RVON Connection Status – Card/Channel page FIGURE 17. Window Item...
  • Page 59 Cronus RVON-C RTS Voice Over Network for Cronus 51 RVON Connection Status – Connection page FIGURE 18. Window Item Description Attempts / Drops The number of times a call attempt has been made and dropped. NOTE: The number of attempts should always be one (1) greater than the number of drops.
  • Page 60 52 RVON-C RTS Voice Over Network for Cronus Cronus RVON Connection Status – VOIP page FIGURE 19. Window Item Description VoIP Playout Statistics Playout Buffer Size Displays how much audio can be received from the network before packets are lost. This is four (4) times bigger than configured packet size.
  • Page 61 Cronus RVON-C RTS Voice Over Network for Cronus 53 RVON Connection Status – Network page FIGURE 20. Window Item Description Network Statistics Voice Playout Packets Displays the number of voice packets transmitted and received from the other side of the (Tx/Rx) connection.
  • Page 62 54 RVON-C RTS Voice Over Network for Cronus Cronus RVON Connection Status – Errors page FIGURE 21. Window Item Description Error Counts Invalid Headers Displays how many IP packets could not be parsed. Invalid MAC Address Displays how many invalid MAC addresses tried to connect.
  • Page 63 Cronus RVON-C RTS Voice Over Network for Cronus 55 RVON Connection Status – Pass-Through page FIGURE 22. Window Items Description SERIAL TO The Serial to Ethernet information shows the serial data that is received on the serial connection ETHERNET and transferred to the Ethernet address of the card the serial data is sent to.
  • Page 64: View Rvon-C Status From Cronus Front Panel

    IN and OUT. Slots connected to an RVON-C card have an arrow in the front panel display, otherwise a dot appears next to the slot. If you have more than one Cronus linked together, the slots will continue numbering slot 5, slot 6, and so on. Turn the selector knob to select the desired slot.
  • Page 65 Cronus RVON-C RTS Voice Over Network for Cronus 57 RVON-C Status Descriptions TABLE 4. ACTION DISPLAY When Ethernet is selected: Link Up - Displays whether the Ethernet link is active or inactive. Link Up - Active, Link Down – Inactive Speed - Displays the connection speed in mbps.
  • Page 66: Download Rvon-C Firmware Through Azedit

    58 RVON-C RTS Voice Over Network for Cronus Cronus Download RVON-C Firmware through AZedit NOTE: AZedit sends the program directly to the RVON-C card over Ethernet. This is different from other I/O cards that receive the firmware from the Master Controller. For this reason, verify the PC running AZedit is on the same network as the RVON-C card.
  • Page 67 Cronus RVON-C RTS Voice Over Network for Cronus 59 Click Open. The Download Device Firmware window appears. Click Begin Download. The download begins. Click OK. The RVON-C firmware download is complete. This may take a minute or two to occur.
  • Page 68 60 RVON-C RTS Voice Over Network for Cronus Cronus RVON-C System Diagram FIGURE 23. Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 69: Basic Network Configuration

    APPENDIX A Basic Network Configuration Basic Network Configuration This section covers basic network configuration setup and testing. Basic concepts and operations, including the difference between LAN and WAN networks and how IP Addressing is used is covered. Typically, there are many computers connected together using a router or a switch in a networked environment, such as a company.
  • Page 70: Wide Area Network

    Cronus Local Area Network Diagram FIGURE 24. Wide Area Network A WAN (Wide Area Network) connects two (2) or more LANs and can span a relatively large geographical area. For example, Telex Headquarters in Burnsville, MN is connected to several branch offices in Nebraska and Arkansas over a WAN. The WAN in existence is the Internet.
  • Page 71: Accessing The Wide Area Network (Wan)

    Cronus ACCESSING THE WIDE AREA NETWORK (WAN) As shown in Figure 26, the LAN IP Address, 10.2.100.X (192.168.X.X is another common address), as seen in . Most devices are shipped with these addresses as the default. It is recommended to use these addresses for LANs.
  • Page 72 Cronus Packet Translation TABLE 6. Packet before Translation Packet After Translation Source Destination Source Destination Port Port Port Port IP Address IP Address IP Address IP Address Number Number Number Number 192.156.136.2 10.2.100.1 1031 192.156.136.22 99.5.1.30 1032 Internet From 192.156.136.22 99.5.1.30...
  • Page 73: Ip Addresses

    Cronus IP Addresses If you do not know your IP Address, you can open a DOS window in a Windows-based environment and bring up the ipconfig window. To find your IP Address using ipconfig, do the following: From the Start Menu, open a Command Prompt window.
  • Page 74: Ping A Computer

    Cronus Ping a Computer Pinging a computer on the network makes sure it is able to send and receive messages on the network. NOTE: You can also ping your RVON-8 card to verify that it is responding over the network by putting the cards IP Address in place of the computer’s IP Address.
  • Page 75: Possible Pitfall With Routers, Gateways, And Switches

    Cronus POSSIBLE PITFALL WITH ROUTERS, GATEWAYS, AND SWITCHES Anytime computers communicate through routers, gateways, and switches, they must gain permission to the connection. Network interface devices can be configured to block specific outgoing requests, as well as incoming requests, based on the IP Address and/or port.
  • Page 76: Rvon Configuration

    Cronus RVON Configuration RVON cards use ports for communication of audio and control packets. Because routers can be configured to block certain incoming and outgoing requests, you will need to open the following ports in your network to allow WAN connections to and from a Network Interface Device.
  • Page 77: Network Terminology

    Cronus Network Terminology Bridges A bridge is a device that connects two LANs, or two segments of the same LAN that use the same protocol. Sometimes called “transparent bridges, they work at the OSI model Layer 2. Simply put, they are not concerned with protocols. Their main job is to pass data to a destination address that is predetermined in the data packet.
  • Page 78 Cronus IP Address (Internet An IP Address is an identifier or numerical name for a computer or device on a network. Data Protocol Address) between computers are routed over the network using these addresses to identify the computer the message is being sent to and the computer the message is being sent from.The format of an IP Address is a 32-bit numeric address written as four numbers separated by periods.
  • Page 79: Rvon Serial And Telnet Commands

    APPENDIX B RVON-C Card Serial Port Programming RVON Serial and Telnet Commands RVON-C card programming can be done via direct serial or telnet connection. There are several physical connections to an RVON-C card. • Direct serial through custom debug cable (J7 6-pin bottom front). The customer debug cable always functions as the general purpose debug tool.
  • Page 80: Rvon-C Boot Download

    Cronus RVON-C Boot Download ***************************** RVON-C Revision 1.00.02 (C) Copyright 2003 Telex Inc. All Rights Reserved. Flash File System initialized. DIP Switch settings:..XXXX Configuration via AZedit disabled (via DIP Switch 1 on) Back card UART enabled for pass-through serial (via DIP Switch 6 off)
  • Page 81 Cronus Adding 5160 symbols for standalone. appCreate: autoBootLevel=2 MXP environment is created. Creating RVON application... -> Bringing DSP subsystem out of reset... DSP Daughtercard type is set to NONE - No DSP Daughtercard Found 0000004883 - ROOT: FPGA Version = ff00...
  • Page 82: Access Serial Command Mode

    Cronus Access Serial Command Mode There are many different serial port commands supported from here, but it is NOT recommended that any be used except: dbgcmd > At a DOS prompt, type dbgcmd, and then press Return. This places the serial port into the MXP> (MXP command mode). The MXP Command Mode is the only mode used.
  • Page 83: Serial Command Table

    Cronus Serial Command Table Serial Command Table TABLE 9. Command Variable 1 Variable 2 Description set rvon Help window which lists all set rvon commands. set rvon ip_addr X.X.X.X Set the IP Address for the RVON Card. set rvon netmask X.X.X.X...
  • Page 84 Cronus Serial Command Table TABLE 9. Command Variable 1 Variable 2 Description show rvon Display current settings show serial Display current settings show channel [chan] Display current settings show emac Display current settings Technical Manual Bosch Security Systems, Inc. F.01U.118.890...
  • Page 85: Codec Specifications

    Cronus Codec Specifications Codec Specifications TABLE 10. 0,3,6,9 G.711 100.00 14000 1,4,7,10 G.711 50.00 11000 2,5,8,11 G.711 33.33 10000 12,16 G.729 100.00 7000 13,17 G.729 50.00 4000 14,18 G.729 25.00 2500 15,19 G.729 16.67 2000 20,22 G.723 5.3k 33.33 2800 22.4...
  • Page 86: Rvon-C Default Setup

    Cronus RVON-C Default Setup The board is shipped from the factory containing the following: All are set rvon commands Variable Environment Name Default Value Description ip_addr EMACA_IPADDR x.x.x.x IP Address for the RVON-C Card netmask EMACA_NETMASK 255.255.255.0 Network Mask for the RVONC card...
  • Page 87: Install Front And Back Cards In Cronus

    Connect Ethernet Verify there is an Ethernet connection from the RVON-C card (J2 Ethernet on the back of the Cronus) to the network. Technical Manual Bosch Security Systems, Inc.
  • Page 88: Launch Azedit And Connect To The Cronus Frame

    You can connect to Cronus using Serial, USB, or Network Connections. The following instructions show how to connect to a network. For more information on configuring the network connection for the Cronus, see page 29. To connect to the Cronus system from AZedit, do the following: From the Options menu, select Communications.
  • Page 89: Configure The Rvon-C Card

    CRONUS appears in the lower, right corner of the AZedit application. Configure the RVON-C Card Once you have a connection to Cronus, you are ready to configure the RVON-C card within the Cronus system. To configure the RVON-C card, do the following: From the Navigation bar at the bottom of the AZedit application, click the RVON button.
  • Page 90 Cronus In the Network Mask field, enter the Network Mask of the network the RVON-C card is connected to. In the Default Gateway field, enter the Default Gateway Address (if applicable) of the network the RVON-C card is connected. A Default Gateway is only required if the RVON-C connections are between LANs or WANs.
  • Page 91: Configure The Devices Connected To The Rvon-C Card

    NOTE: When making adjustments to the DIP switches and jumpers, you msut take the front card out of the Cronus. To use the Serial Pass-Through, do the following: Set DIP Switch 6 to the OPEN position.
  • Page 92 Cronus Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 93 Cronus MDR Data + backcard: XCP-32-DB9, XCP-48-RJ45, and XCP-48-Telco. Data - On the Cronus you can have up to four MDR backcards Audio to Matrix + mounted on the chassis to give you that many more keypanel ports.
  • Page 94: Xcp-32-Db9 Breakout Panel

    Function 32-port DB9 breakout panel with MDR connecotr for the AIO-16. It allows you to expand the number of DB-9 serial Audio to Matrix - ports on the Cronus. Audio from Matrix + Audio from Matrix - NOTE: When using the 32-port DB-9 breakout panel,...
  • Page 95 Cronus Pin Number Port Function Description Audio from Matrix + Pin 1 Keypanel Data + Audio from Matrix - Pin 2 Keypanel Data - Data + Pin 3 Data - Pin 4 Audio to Matrix + Audio to Matrix +...
  • Page 96: Cronus

    Function The XCP-48-RJ45 is the newly created 48-port RJ45 Audio to Matrix - breakout panel with MDR connector for the Cronus. It Audio from Matrix + allows you to expand the number of RJ-45 ports on the Audio from Matrix - ADAM system, up to 48 ports.
  • Page 97 Cronus Pin Number Port Function Data + Data - Audio to Matrix + Audio to Matrix - Audio from Matrix + Audio from Matrix - Data + Data - Audio to Matrix + Audio to Matrix - Audio from Matrix +...
  • Page 98: Xcp-48-Telco Breakout Panel

    The XCP-48-Telco is the newly created breakout panel with Pin Number Port Function MDR connector for the Cronus. It combines audio to matrix, audio from matrix, and data pairs. It then routes them on individual Telco connectors. Data + Data -...
  • Page 99: Telco Backcard

    Cronus Telco Backcard Connector (J1, J4) Table 11. Pin Number Port Function Pin Number Port Function Data + Audio to Matrix + Data - Audio to Matrix - Audio to Matrix + Audio to Matrix - Audio to Matrix +...
  • Page 100: Technical Manual Cronus F.01U.118.890 Rev

    Cronus Telco Backcard Connector (J1, J4) Table 11. Pin Number Port Function Audio to Matrix - Audio to Matrix + Audio to Matrix - Audio to Matrix + Audio to Matrix - Audio to Matrix + Audio to Matrix -...
  • Page 101: Cronus Master Controller Card

    APPENDIX E Cronus Master Controller Card 9030-7785-000 Legacy Master Controller Card Jumper Settings Legacy Master Controller Card FIGURE 30. Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 102 Cronus Connector Description Default Setting J3 & 4 J Tag Connector and Flash Write Protect Populate across pins 1 & 2 and 9 & 10 Cold Fire Test Mode +5 Volt Jumper Populate across pins 1 & 2 44k / 48k mode select J Tag Mode Populate across pins 2 &...
  • Page 103: Additional Information

    APPENDIX F Additional Information Cable drawings for PAP-32, AZedit, Trunking and UIO-256/GPIO-16/LCP-102 FIGURE 31. Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 104 Cronus Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 105: Rvon Trunking Connections

    AZedit Via RVON-8 RS-232 Mode • CS9500 Trunking Via RVON-I/O To RVON-8 • ADAM Trunking Via RVON-8 • Zeus II Trunking Via RVON-I/O To RVON-C • Cronus Trunking Via RVON-I/O To RVON-8 Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 106 Cronus Technical Manual Bosch Security Systems, Inc. F.01U.118.890 Rev. 23...
  • Page 107 Cronus AZedit Via RVON-8 RS-232 Mode FIGURE 32. Rev. 23 Bosch Security Systems, Inc. Technical Manual F.01U.118.890...
  • Page 108 Cronus CS9500 Trunking Via RVON-I/O To RVON-8 FIGURE 33. Rev. 23 F.01U.118.890 Technical Manual Bosch Security Systems, Inc.
  • Page 109 Cronus ADAM Trunking Via RVON-8 FIGURE 34. Rev. 23 Bosch Security Systems, Inc. Technical Manual F.01U.118.890...
  • Page 110 Cronus Zeus II Trunking Via RVON-I/O to RVON-C FIGURE 35. Rev. 23 F.01U.118.890 Technical Manual Bosch Security Systems, Inc.
  • Page 111 Cronus Cronus Trunking Via RVON-I/O To RVON-8 FIGURE 36. Rev. 23 Bosch Security Systems, Inc. Technical Manual F.01U.118.890...
  • Page 112 Cronus RVON-16 Trunking FIGURE 37. Rev. 23 F.01U.118.890 Technical Manual Bosch Security Systems, Inc.
  • Page 113: Notes

    Cronus Notes Rev. 23 Bosch Security Systems, Inc. Technical Manual F.01U.118.890...