3. Periodic check
3.4.6

2nd Transfer Roller

[1]
[6]
[8]
[6]
[4]
NOTE
• When the 2nd Transfer Roller is replaced with a new one, it is necessary to reset
the maintenance counter.
For details of how to reset the maintenance counter, see "Adjustment/Setting."
18
[3]
[2]
[2]
4139fs2516c0
[5]
[7]
[8]
[7]
4139fs2523c0
Field Service Ver. 4.0 Feb. 2006
A. Replacement Procedure
1. Open the Top Cover.
2. Remove the Drum Cartridge.
☞ 17
3. Remove the 2nd Transfer Roller
Assy [3] as follows. While pushing
the levers [2] of the holders [1]
located on both sides, pull the hold-
ers [1] to the front.
NOTE
• Use care not to lose the two springs
of the 2nd Transfer Roller Assy.
They can easily come off.
4. Remove the conductive material [4],
gear [5], two springs [6], two holders
[7], and two collars [8].
5. To reinstall, reverse the order of
removal.