20. Image Quality Problems
20.1.6
Gradation reproduction failure
A. Typical faulty images
B. Troubleshooting procedure
Step
Section
1
Drum Cartridge Is the outside dirty?
2
PH Unit
3
AIDC Sensor
4
154
4036fs4048c0
Check Item
Is the window surface dirty?
Is the sensor dirty?
Have steps 1-3 eliminated the
problem?
Field Service Ver. 4.0 Feb. 2006
4036fs4049c0
Result
Action
YES
Clean.
YES
Clean.
YES
Clean.
Replace the Toner Cartridge.
→ Replace the PH Unit.
NO
→ Replace the AIDC Sensor.
→ Replace the High Voltage Unit.