Field Service Ver. 4.0 Feb. 2006
14.3.2
SERVICE PERSON SRU USAGE
Function
• Displays the remaining life of the Transfer Belt, Transfer Roller, and Fusing Unit.
Use
• To check the remaining life of the maintenance service parts.
Setting
1. Enter Service Mode.
/procedure
2. Select SERVICE PERSON SRU USAGE and press the Menu Select key.
3. Select the desired unit using the right and left arrow keys.
14.3.3
RESET CONTROLLER
Function
• Resets the controller.
Use
• To return the controller to its initial condition.
Setting
1. Enter Service Mode.
/procedure
2. Select RESET CONTROLLER and press the Menu Select key.
3. This automatically restarts the machine and the initial
4. screen reappears.
14.3.4
RESET COUNTER TRANSFER BELT
Function
• Resets the counter value of the Transfer Belt Unit.
Use
• To reset the Transfer Belt Unit counter after the Transfer Belt Unit is replaced.
Setting
1. Enter Service Mode.
/procedure
2. Select RESET COUNTER TRANSFER BELT UNIT and press the Menu Select key.
3. This resets the counter and the Engine/Service menu reappears.
14.3.5
RESET COUNTER FUSER UNIT
Function
• Resets the counter value of the Fusing Unit.
Use
• To reset the Fusing Unit counter after the Fusing Unit is replaced.
Setting
1. Enter Service Mode.
/procedure
2. Select RESET COUNTER FUSER UNIT and press the Menu Select key.
3. This resets the counter and the Engine/Service menu reappears.
14.3.6
RESET COUNTER TRANSFER ROLLER
Function
• Resets the counter value of the Transfer Roller.
Use
• To reset the Transfer Roller counter after the Transfer Roller is replaced.
Setting
1. Enter Service Mode.
/procedure
2. Select RESET COUNTER TRANSFER ROLLER and press the Menu Select key.
3. This resets the counter and the Engine/Service menu reappears.
14. Service Mode (magicolor 2430 DL)