12. Menu (magicolor 2450)
12.5.2

TONER OUT ACTION

Function
• Specifies whether to stop or continue printing when a toner empty condition is
Use
• To select to permit printing upon a toner empty condition.
Setting
• The default setting is STOP.
/procedure
12.5.3

AIDC

A. REQUEST AIDC
Function
• Executes image adjustments.
Use
• To calibrate the engine when there are print image quality problems.
• To calibrate the engine when the Transfer Belt Unit and Transfer Roller are replaced
Setting
• The default setting is NO.
/procedure
• If YES is selected, image adjustments are performed.
B. MODE
Function
• Applies the image adjustments
Use
• If ON is selected, to apply the image adjustments.
• If OFF is selected, to not apply image adjustments.
Setting
• The default setting is ON.
/procedure
12.5.4

DENSITY CONTROL

A. BLACK/CYAN/MAGENTA/YELLOW
Function
• Adjusts the density of the toner to one of five levels.
Use
• To vary the density of the printed image.
Setting
• The default setting is 3.
/procedure
102
2
detected.
"STOP"
with new ones.
YES
"ON"
Field Service Ver. 4.0 Feb. 2006
CONTINUE
"NO"
OFF
1 to 5