2Nd Transfer Roller - Konica Minolta magicolor 2500W Service Manual

Hide thumbs Also See for magicolor 2500W:
Table of Contents

Advertisement

3. Periodic check
3.4.5

2nd transfer roller

[1]
[3]
[5]
[3]
[1]
NOTE
• When the 2nd transfer roller is replaced with a new one, it is necessary to reset the
maintenance counter.
For magicolor 2500W: See P.77
For magicolor 2530 DL: See P.128
For magicolor 2550/magicolor 2550DN: See P.130
18
[3]
[2]
[2]
4139fs2516c0
[2]
[4]
[5]
[4]
A00VF2C505DA
Field Service Ver. 1.0 Aug. 2006
A. Replacement procedure
1. Open the top cover.
2. Remove the drum cartridge.
See P.17
3. Remove the 2nd transfer roller assy
[3] as follows. While pushing the
levers [2] of the holders [1] located
on both sides, pull the holders [1] to
the front.
NOTE
• Use care not to lose the two springs
of the 2nd transfer roller assy. They
can easily come off.
4. Remove the conductive material [1],
gear [2], two springs [3], two holders
[4], and two collars [5].
5. To reinstall, reverse the order of
removal.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magicolor 2530 dlMagicolor 2550Magicolor 2550dn

Table of Contents