4. Jam Display
4.4.3
Misfeed at Duplex Unit paper feed section
A. Detection Timing
Type
The Duplex Paper Loop Sensor (PC10 DU) is not unblocked even after the lapse
of a predetermined period of time after a Duplex paper feed sequence has been
started.
Detection of mis-
The Duplex Paper Loop Sensor (PC10 DU) is not blocked even after the lapse of
feed at Duplex Unit
a predetermined period of time after a Duplex paper feed sequence has been
paper feed section
started.
The Duplex Transport Sensor (PC12 DU) is not blocked even after the lapse of a
predetermined period of time after a Duplex paper feed sequence has been
started.
B. Action
Duplex Paper Loop Sensor (PC10 DU)
Duplex Transport Sensor (PC12 DU)
Duolex Transport Motor (M8 DU)
Step
1
Initial check items.
2
Check the PC10 DU sensor.
3
Check the PC12 DU sensor.
4
Check M8 DU for correct operation.
5
Change PWB-A DU.
6
Change PWB-A.
18
Relevant Electrical Parts
Duplex Board (PWB-A DU)
Mechanical Control Board (PWB-A)
Action
Field Service Ver. 2.0 Apr. 2005
Description
WIRING DIAGRAM
Control Signal
-
PWB-A DU PJ3A DU-3 (ON)
PWB-A DU PJ5A DU-3 (ON)
PWB-A DU
PJ2A DU-1~4 (pulse)
-
-
Location
(Electrical
Component)
-
3-G
3-C
5~6-C
-
-