Omron SYSDRIVE 3G3MV Setup Manual page 90

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

List of Parameters
Param-
Regis-
Name
eter
ter No.
No.
(Hex)
n159
019F
Energy-sav-
ing voltage
upper limit at
60-Hz output
n160
01A0
Energy-sav-
ing upper
limit voltage
at 6-Hz out-
put
n161
01A1
Power detec-
tion width for
probe opera-
tion switching
n162
01A2
Power detec-
tion filter con-
stant
n163
01A3
PID output
gain
3-36
Description
These parameters prevent the motor
from over excitation due to voltage
changes during energy-saving con-
trol.
Sets the upper limit of output voltage
Sets the upper limit of output voltage
as a percentage at each frequency
based on the rated motor voltage as
100%.
Note Normally, the default settings
do not need to be changed.
Sets the detection width of power
that sets the Inverter into probe
operation.
Sets the width as a percentage
based on the power to be detected
as 100%.
Note Normally, the default setting
does not need to be changed.
Note The Inverter will operate with
a power detection width of
10% if the value is set to 0.
Sets the filter time constant of the
power detection block of the Inverter
operating in probe operation.
Filter time constant (ms) = Set value
in n162 x 4 (ms)
Note Normally, the default setting
does not need to be changed.
Note The Inverter will operate with
a time constant of 20 ms if the
value is set to 0.
Sets the rate by which PID control
value is multiplied for PID control.
Note Normally, the default setting
does not need to be changed.
Chapter 3
Set-
Default
Chan-
ting
setting
ges
range
during
opera-
tion
0 to
120
No
120
0 to
16
No
25
0 to
10
No
100
0 to
5
No
255
0.0 to
1.0
No
25.0
Memo