Standard Connections - Omron SYSDRIVE 3G3MV Setup Manual

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV:
Table of Contents

Advertisement

Design

1-2-2 Standard Connections

3-phase 200/400 V AC
Single-phase 200 V AC (See note.)
Multi-function input 1 (Forward/Stop)
Multi-function input 2 (Reverse/Stop)
Multi-function input 3 (External fault Normally open)
Multi-function input 4 (Fault Reset)
Multi-function input 5 (Multi-step speed reference 1)
Multi-function input 6 (Multi-step speed reference 2)
Multi-function input 7 (Inching frequency command)
Sequence input common
Frequency reference power
supply 20 mA at +12 V
External
Frequency reference input
frequency
adjuster (2 kΩ,
Frequency reference
1/4 W min.)
common
Pulse
generator
Pulse train input
RS-422
communications
(RS-485 selection)
Multi-function analog voltage input
Multi-function analog current input
Analog input common
Note Connect single-phase 200 V AC to terminals R/L1 and S/L2 of the 3G3MV-ABj.
DC reactor
(optional)
Noise Filter
Braking Resistor
(optional)
Connector
Digital Operator
Note Connector on CN2 wiring side:
Contact: SZH-002T-P0.5
Housing: ZHR-3
(Products of J.S.T. MFG. Co., Ltd.)
Chapter 1
Multi-function contact output
NO
NC
Common
Multi-function
photocoupler output 1
Multi-function
photocoupler output 2
Multi-function
photocoupler output
common
Multi-function analog
output/Pulse monitor
output
Multi-function analog output
common
1-21

Hide quick links:

Advertisement

Table of Contents
loading